Specification: Part Number 1207923 Permitted cable length: ≤ 20 m TM (mission time): 20 a (EN ISO 13849) Connection type: Male connector M12, 5-pin Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Type: Type 2 (IEC 61496) Restart interlock: + Configuration method: Hard wired Resolution: 14 mm External device monitoring (EDM): + Ambient operating temperature: -20
Specification: Part Number 1207793 External device monitoring (EDM): + Cascaded: - Restart interlock: + Category: Category 2 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Typical range: 0 m ... 8 m Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Protection class: III (EN 61140) Connection type: Male connector M12, 5-pin Ambient operating temperature: -20 °C ... +55 °C External d
Specification: Part Number 1207866 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Storage temperature: -25 °C ... +70 °C Power consumption: ≤ 3 A Connection type: Male connector M12, 5-pin Safe SICK device communication via EFI/SDL: - Housing material: Aluminum alloy ALMGSI 0.5 Resolution: 14 mm Test rate (internal test): 47 /s Ripple: ≤ 10 % Category: Category 2 (EN ISO 13849) Vibration re
Specification: Part Number 1207822 Ripple: ≤ 10 % Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Air humidity: 15 % ... 95 %, non-condensing Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Housing cross-section (incl. system connection): 15 mm x 32 mm
Specification: Part Number 1207847 Type: Type 2 (IEC 61496) Power consumption: ≤ 3 A Category: Category 2 (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm Scanning range: 0 m ... 6 m Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Synchronization: Optical, without separate synchronization Response time: ≤ 13 ms Typical range: 0 m ... 8 m Resolution: 34 mm
Specification: Part Number 1207904 Test rate (internal test): 47 /s Housing material: Aluminum alloy ALMGSI 0.5 Category: Category 2 (EN ISO 13849) Storage temperature: -25 °C ... +70 °C Ambient operating temperature: -20 °C ... +55 °C Air humidity: 15 % ... 95 %, non-condensing Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Response time: ≤ 13 ms Resolution: 34 mm Housing cross-section (incl
Specification: Part Number 1207924 Weight: 75 g Beam coding: + Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Synchronization: Optical, without separate synchronization Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Typical range: 0 m ... 8 m Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Response time
Specification: Part Number 1207794 Configuration method: Hard wired Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Category: Category 2 (EN ISO 13849) Switching voltage LOW: 2 V DC Cable length: 160 mm External device monitoring (EDM): + Scanning range: 0 m ... 6 m External device monitoring (delivery status): Deactivated Type of output: PNP semiconductors, short-circuit protected, cross-circui
Specification: Part Number 1207867 Ambient operating temperature: -20 °C ... +55 °C Switching current: 300 mA Test rate (internal test): 47 /s Power consumption: ≤ 3 A Storage temperature: -25 °C ... +70 °C External device monitoring (EDM): + Safe state in the event of a fault: At least one OSSD is in the OFF state. Type: Type 2 (IEC 61496) Performance level: PL c (EN ISO 13849), Pay attention to o
Specification: Part Number 1207823 TM (mission time): 20 a (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Housing material: Aluminum alloy ALMGSI 0.5 PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Configuration method: Hard wired Test rate (internal test): 58 /s Cable length: 160 mm Switching voltage HIGH: 24 V DC (V
Specification: Part Number 1207848 Safe SICK device communication via EFI/SDL: - PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Connection type: Male connector M12, 5-pin Typical range: 0 m ... 8 m Housing cross-section (incl. system connection): 15 mm x 32 mm Permitted cable length: ≤ 20 m Protective field height: 180 mm Synchronization: Optical, without separate synchronization Air humidity: 15
Specification: Part Number 1207905 Cable length: 160 mm Storage temperature: -25 °C ... +70 °C Connection type: Male connector M12, 5-pin Test rate (internal test): 47 /s Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Response time: ≤ 13 ms Maximum demand rate: 28 /min (EN ISO 13849) Power consumption: ≤ 3 A Switching volta
Specification: Part Number 1207925 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Ambient operating temperature: -20 °C ... +55 °C Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Category: Category 2 (EN ISO 13849) PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Safe SICK device communication via EFI/SDL: - Sy
Specification: Part Number 1207795 Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Display elements: LEDs Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Resolution: 14 mm Typical range: 0 m ... 8 m Housing material: Aluminum alloy ALMGSI 0.5 Housing cross-section (incl. system connection): 15 mm x 32 mm Ripple: ≤ 10 % Storage tem
Specification: Part Number 1207868 Display elements: LEDs Beam coding: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Maximum demand rate: 28 /min (EN ISO 13849) Typical range: 0 m ... 8 m Permitted cable length: ≤ 20 m Protection class: III (EN 61140) Scanning range: 0 m ... 6 m Conductor cross-section: 0.34 mm² Type: Type 2 (IEC
Specification: Part Number 1207944 Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Permitted cable length: ≤ 20 m Restart interlock: + Protection class: III (EN 61140) Scanning range: 0 m ... 6 m Storage temperature: -25 °C ... +70 °C Weight: 95 g Maximum demand rate: 34 /min (EN ISO 13849) Type of output: PNP semiconductors, s
Specification: Part Number 1207824 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Power consumption: ≤ 3 A Protection class: III (EN 61140) Scanning range: 0 m ... 6 m Weight: 95 g Category: Category 2 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Ambient operating temperature: -20 °C ... +55 °C Typical range: 0 m ... 8 m Automatic beam coding: + Safe SICK device communication via
Specification: Part Number 1207963 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Conductor cross-section: 0.34 mm² Category: Category 2 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing material: Aluminum alloy ALMGSI 0.5 Cascaded: - Switching current: 300 mA Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!
Specification: Part Number 1207849 Housing cross-section (incl. system connection): 15 mm x 32 mm Ambient operating temperature: -20 °C ... +55 °C Conductor cross-section: 0.34 mm² Storage temperature: -25 °C ... +70 °C Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Beam coding: + Housing material: Aluminum alloy ALMGSI 0.5 Safe SICK device communication via EFI/SDL: - Integration via Flexi
Specification: Part Number 1207926 Conductor cross-section: 0.34 mm² Safe SICK device communication via EFI/SDL: - Storage temperature: -25 °C ... +70 °C Type: Type 2 (IEC 61496) External device monitoring (EDM): + External device monitoring (delivery status): Deactivated Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) Protective field height: 300 mm Configuration me
Specification: Part Number 1207796 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Configuration method: Hard wired Scanning range: 0 m ... 6 m Beam coding: + Protection class: III (EN 61140) Test rate (internal test): 58 /s Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Enclosure rating: IP 65 (EN 60529) Restar
Specification: Part Number 1207869 Restart interlock: + Storage temperature: -25 °C ... +70 °C Safe state in the event of a fault: At least one OSSD is in the OFF state. Test rate (internal test): 47 /s Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Display elements: LEDs Switching current: 300 mA Ripple: ≤ 10 % External device monitoring (delivery status): Deactivated Conductor cross-s
Specification: Part Number 1207945 Safe SICK device communication via EFI/SDL: - Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Typical range: 0 m ... 8 m Type: Type 2 (IEC 61496) Switching current: 300 mA S
Specification: Part Number 1207888 Connection type extension connection: Female connector M12, 5-pin Cable length: 350 mm Synchronization: Optical, without separate synchronization Air humidity: 15 % ... 95 %, non-condensing Automatic beam coding: + Connection type: Male connector M12, 5-pin Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Maximum demand rate: 28 /min (EN I
Specification: Part Number 1207850 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Switching current: 300 mA Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Typical range: 0 m ... 8 m Restart interlock: + Synchronization: Optical, without separate synchronization Maximum demand rate: 34 /min
Specification: Part Number 1207907 PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Test rate (internal test): 47 /s Restart interlock (delivery status): Deactivated Protective field height: 300 mm TM (mission time): 20 a (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Ambient operating temperature: -20 °C ... +55 °C Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Safe state in th
Specification: Part Number 1207927 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Permitted cable length: ≤ 20 m Switching current: 300 mA Housing material: Aluminum alloy ALMGSI 0.5 Power consumption: ≤ 3 A TM (mission time): 20 a (EN ISO 13849) Weight: 135 g Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Configuration method: Hard wired Response time: &le
Specification: Part Number 1207797 Air humidity: 15 % ... 95 %, non-condensing Ambient operating temperature: -20 °C ... +55 °C Configuration method: Hard wired Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Connection type: Male connector M12, 5-pin Permitted cable length: ≤ 20 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protection class: III (EN 61