Specification: Part Number 1207905 Cable length: 160 mm Storage temperature: -25 °C ... +70 °C Connection type: Male connector M12, 5-pin Test rate (internal test): 47 /s Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Response time: ≤ 13 ms Maximum demand rate: 28 /min (EN ISO 13849) Power consumption: ≤ 3 A Switching voltage LOW: 2 V DC Weight: 75 g Automatic beam coding: + External device monitoring (delivery status): Deactivated Type: Type 2 (IEC 61496) Synchronization: Optical, without separate synchronization External device monitoring (EDM): + Permitted cable length: ≤ 20 m Restart interlock (delivery status): Deactivated Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Safe SICK device communication via EFI/SDL: - Scanning range: 0 m ... 6 m Housing material: Aluminum alloy ALMGSI 0.5 Restart interlock: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Typical range: 0 m ... 8 m Connection type extension connection: Female connector M12, 5-pin Cascaded: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Housing cross-section (incl. system connection): 15 mm x 32 mm Resolution: 34 mm Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Shock resistance: 10 g, 16 ms (EN 60068-2-27) Configuration method: Hard wired Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Ripple: ≤ 10 % TM (mission time): 20 a (EN ISO 13849) Protective field height: 180 mm Conductor cross-section: 0.34 mm² Category: Category 2 (EN ISO 13849) Protection class: III (EN 61140) Air humidity: 15 % ... 95 %, non-condensing Enclosure rating: IP 65 (EN 60529) Switching current: 300 mA Beam coding: + Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored