Specification: Part Number 1207796 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Configuration method: Hard wired Scanning range: 0 m ... 6 m Beam coding: + Protection class: III (EN 61140) Test rate (internal test): 58 /s Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Enclosure rating: IP 65 (EN 60529) Restart interlock: + Category: Category 2 (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm Protective field height: 300 mm Synchronization: Optical, without separate synchronization Safe state in the event of a fault: At least one OSSD is in the OFF state. Cascaded: - Safe SICK device communication via EFI/SDL: - Conductor cross-section: 0.34 mm² Housing material: Aluminum alloy ALMGSI 0.5 Switching voltage LOW: 2 V DC Weight: 115 g Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Permitted cable length: ≤ 20 m Typical range: 0 m ... 8 m Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Maximum demand rate: 34 /min (EN ISO 13849) Display elements: LEDs Cable length: 350 mm Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Power consumption: ≤ 3 A Storage temperature: -25 °C ... +70 °C Restart interlock (delivery status): Deactivated PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Switching current: 300 mA Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Automatic beam coding: + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) External device monitoring (EDM): + Response time: ≤ 14 ms Resolution: 14 mm Type: Type 2 (IEC 61496) External device monitoring (delivery status): Deactivated Ripple: ≤ 10 % Ambient operating temperature: -20 °C ... +55 °C