Specification: Part Number 1207870 Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Switching current: 300 mA Housing cross-section (incl. system connection): 15 mm x 32 mm Ambient operating temperature: -20 °C ... +55 °C Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Typical range: 0 m ... 8 m Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Connection type extension connection: Female
Specification: Part Number 1207946 Resolution: 24 mm Power consumption: ≤ 3 A External device monitoring (EDM): + Permitted cable length: ≤ 20 m Synchronization: Optical, without separate synchronization Configuration method: Hard wired Ambient operating temperature: -20 °C ... +55 °C Response time: ≤ 13 ms Typical range: 0 m ... 8 m Cable length: 350 mm Protective field height: 360 m
Specification: Part Number 1207832 Housing cross-section (incl. system connection): 15 mm x 32 mm Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Air humidity: 15 % ... 95 %, non-condensing Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Conductor cross-section: 0.34 mm² Typical range: 0 m ... 8 m Safe state in the event of a fault: At least one OSSD is in the OFF state. Ripple: ≤ 10 % Sync
Specification: Part Number 1207889 Test rate (internal test): 47 /s Connection type: Male connector M12, 5-pin Housing material: Aluminum alloy ALMGSI 0.5 Ambient operating temperature: -20 °C ... +55 °C PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Conductor cross-section: 0.34 mm² Synchronization: Optical, without separate synchronization Sw
Specification: Part Number 1207965 Safe state in the event of a fault: At least one OSSD is in the OFF state. Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Response time: ≤ 13 ms Housing cross-section (incl. system connection): 15 mm x 32 mm Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Resolution: 34 mm Category: Category 2 (EN ISO 13849) Automatic beam
Specification: Part Number 1207851 Type: Type 2 (IEC 61496) Protection class: III (EN 61140) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Configuration method: Hard wired Typical range: 0 m ... 8 m Switching voltage LOW: 2 V DC Housing cross-section (incl. system connection): 15 mm x 32 mm Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Be
Specification: Part Number 1207908 Scanning range: 0 m ... 6 m Synchronization: Optical, without separate synchronization Safe state in the event of a fault: At least one OSSD is in the OFF state. Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Power consumption: ≤ 3 A Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Housing cross-section (incl. system connection): 15
Specification: Part Number 1207928 External device monitoring (delivery status): Deactivated TM (mission time): 20 a (EN ISO 13849) Beam coding: + Switching current: 300 mA Weight: 155 g Category: Category 2 (EN ISO 13849) Safe state in the event of a fault: At least one OSSD is in the OFF state. Power consumption: ≤ 3 A Ambient operating temperature: -20 °C ... +55 °C Resolution: 14 mm Permit
Specification: Part Number 1207798 Maximum demand rate: 34 /min (EN ISO 13849) Permitted cable length: ≤ 20 m Safe state in the event of a fault: At least one OSSD is in the OFF state. Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Protection class: III (EN 61140) Switching voltage LOW: 2 V DC Weight: 155 g Protective field height: 420 mm Switching voltage HIGH: 24
Specification: Part Number 1207871 Safe state in the event of a fault: At least one OSSD is in the OFF state. Cable length: 350 mm Weight: 155 g Enclosure rating: IP 65 (EN 60529) Housing material: Aluminum alloy ALMGSI 0.5 Connection type: Male connector M12, 5-pin Protection class: III (EN 61140) TM (mission time): 20 a (EN ISO 13849) Power consumption: ≤ 3 A Resolution: 14 mm Display elements
Specification: Part Number 1207833 External device monitoring (EDM): + Configuration method: Hard wired Cable length: 350 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Type: Type 2 (IEC 61496) Safe SICK device communication via EFI/SDL: - External device monitoring (delivery status): Deactivated Connection type: Male connector M12, 5-pin Typical range: 0 m ... 8 m Ambient
Specification: Part Number 1207966 Housing material: Aluminum alloy ALMGSI 0.5 Switching voltage LOW: 2 V DC Response time: ≤ 13 ms Restart interlock (delivery status): Deactivated Cable length: 350 mm Maximum demand rate: 34 /min (EN ISO 13849) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Power consumption: ≤ 3 A Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Weight: 155 g
Specification: Part Number 1207852 TM (mission time): 20 a (EN ISO 13849) PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Response time: ≤ 13 ms External device monitoring (delivery status): Deactivated Conductor cross-section: 0.34 mm² Protective field height: 420 mm Cascaded: - Safe SICK device communication vi
Specification: Part Number 1207909 Maximum demand rate: 28 /min (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Ambient operating temperature: -20 °C ... +55 °C Permitted cable length: ≤ 20 m Scanning range: 0 m ... 6 m PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Switching voltage LOW: 2 V DC Cascaded: + Housing material: Aluminum alloy ALMGSI 0.5 Restart interloc
Specification: Part Number 1207929 Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Ripple: ≤ 10 % Restart interlock: + Power consumption: ≤ 3 A Synchronization: Optical, without separate synchronization Permitted cable length: ≤ 20 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Automatic beam coding: + Configuration method: Hard wired Cable length: 350 mm Connecti
Specification: Part Number 1207799 TM (mission time): 20 a (EN ISO 13849) Conductor cross-section: 0.34 mm² Ripple: ≤ 10 % PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safe SICK device communication via EFI/SDL: - Protective field height: 480 mm Maximum demand rate: 34 /min (EN ISO 13849) Beam coding: + Prot
Specification: Part Number 1207872 Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Weight: 175 g Ambient operating temperature: -20 °C ... +55 °C Safe SICK device communication via EFI/SDL: - Protective field height: 480 mm Cable length: 350 mm Beam coding: + Configuration method: Hard wired Storage temperature: -25 °C ... +70 °C External device monitoring (delivery status): Deactivated
Specification: Part Number 1207948 Weight: 175 g Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Safe SICK device communication via EFI/SDL: - Protective field height: 480 mm Conductor cross-section: 0.34 mm² Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Power consumption: ≤ 3 A Restart interlock (delivery status): Deactivated A
Specification: Part Number 1207834 Test rate (internal test): 58 /s Scanning range: 0 m ... 6 m Air humidity: 15 % ... 95 %, non-condensing Enclosure rating: IP 65 (EN 60529) External device monitoring (EDM): + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Resolution: 24 mm Restart interlock (delivery status): Deactivated Protection class: III (EN 61140) Type: Type 2 (IEC 61496) Safety int
Specification: Part Number 1207967 Permitted cable length: ≤ 20 m Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Test rate (internal test): 58 /s Maximum demand rate: 34 /min (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Scanning range: 0 m ... 6 m Safe state in the event of a fault: At least one OSSD is in the OFF state.
Specification: Part Number 1207853 Typical range: 0 m ... 8 m External device monitoring (EDM): + Beam coding: + Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Configuration method: Hard wired Protection class: III (EN 61140) Restart interlock: + Automatic beam coding: + Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Air humidity: 15 % ... 95 %, non-co
Specification: Part Number 1207930 Connection type: Male connector M12, 5-pin Housing material: Aluminum alloy ALMGSI 0.5 Maximum demand rate: 34 /min (EN ISO 13849) Ripple: ≤ 10 % Conductor cross-section: 0.34 mm² Housing cross-section (incl. system connection): 15 mm x 32 mm Storage temperature: -25 °C ... +70 °C Safe SICK device communication via EFI/SDL: - Vibration resistance: 5 g, 10 Hz ... 5
Specification: Part Number 1207800 Protection class: III (EN 61140) Typical range: 0 m ... 8 m Configuration method: Hard wired Safe state in the event of a fault: At least one OSSD is in the OFF state. External device monitoring (EDM): + Conductor cross-section: 0.34 mm² Test rate (internal test): 58 /s Protective field height: 540 mm TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Saf
Specification: Part Number 1207873 Enclosure rating: IP 65 (EN 60529) Configuration method: Hard wired Shock resistance: 10 g, 16 ms (EN 60068-2-27) Ripple: ≤ 10 % Cascaded: + Safe SICK device communication via EFI/SDL: - Safe state in the event of a fault: At least one OSSD is in the OFF state. Restart interlock (delivery status): Deactivated Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061)
Specification: Part Number 1207835 Automatic beam coding: + Maximum demand rate: 34 /min (EN ISO 13849) Switching current: 300 mA Power consumption: ≤ 3 A Synchronization: Optical, without separate synchronization Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Restart interlock (delivery status): Deactivated Weight: 195 g Configuration method: Hard wired Beam coding: + Storage temperature:
Specification: Part Number 1207968 Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Ambient operating temperature: -20 °C ... +55 °C TM (mission time): 20 a (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Enclosure rating: IP 65 (EN 60529) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Type of output: P
Specification: Part Number 1207854 External device monitoring (EDM): + Test rate (internal test): 58 /s Automatic beam coding: + Synchronization: Optical, without separate synchronization Connection type: Male connector M12, 5-pin Storage temperature: -25 °C ... +70 °C Type: Type 2 (IEC 61496) Resolution: 34 mm Ambient operating temperature: -20 °C ... +55 °C Protection class: III (EN 61140) Max
Specification: Part Number 1207911 Housing cross-section (incl. system connection): 15 mm x 32 mm Automatic beam coding: + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Restart interlock: + Safe SICK device communication via EFI/SDL: - Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protection class: III (EN 61140) Ambient operating temperature: -20 °C ... +55 °C Wei
Specification: Part Number 1207931 TM (mission time): 20 a (EN ISO 13849) Type: Type 2 (IEC 61496) Air humidity: 15 % ... 95 %, non-condensing Response time: ≤ 14 ms Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Test rate (internal test): 58 /s Category: Category 2 (EN ISO 13849) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFI
Specification: Part Number 1207801 Typical range: 0 m ... 8 m Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Ripple: ≤ 10 % External device monitoring (EDM): + TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Protection class: III (EN 61140) Scanning range: 0 m ... 6 m Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Safe S