Specification: Part Number 1207967 Permitted cable length: ≤ 20 m Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Test rate (internal test): 58 /s Maximum demand rate: 34 /min (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Scanning range: 0 m ... 6 m Safe state in the event of a fault: At least one OSSD is in the OFF state. Housing cross-section (incl. system connection): 15 mm x 32 mm Cable length: 350 mm Beam coding: + Weight: 175 g Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Storage temperature: -25 °C ... +70 °C PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Protective field height: 480 mm Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Switching voltage LOW: 2 V DC TM (mission time): 20 a (EN ISO 13849) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Resolution: 34 mm Type: Type 2 (IEC 61496) Category: Category 2 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Automatic beam coding: + External device monitoring (EDM): + Restart interlock (delivery status): Deactivated Housing material: Aluminum alloy ALMGSI 0.5 Restart interlock: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Protection class: III (EN 61140) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Power consumption: ≤ 3 A Cascaded: - Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Synchronization: Optical, without separate synchronization External device monitoring (delivery status): Deactivated Switching current: 300 mA Ripple: ≤ 10 % Response time: ≤ 13 ms Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Typical range: 0 m ... 8 m Connection type: Male connector M12, 5-pin Safe SICK device communication via EFI/SDL: - Conductor cross-section: 0.34 mm² Configuration method: Hard wired