Specification: Part Number 1207834 Test rate (internal test): 58 /s Scanning range: 0 m ... 6 m Air humidity: 15 % ... 95 %, non-condensing Enclosure rating: IP 65 (EN 60529) External device monitoring (EDM): + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Resolution: 24 mm Restart interlock (delivery status): Deactivated Protection class: III (EN 61140) Type: Type 2 (IEC 61496) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Category: Category 2 (EN ISO 13849) Permitted cable length: ≤ 20 m Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Ripple: ≤ 10 % Display elements: LEDs Automatic beam coding: + Connection type: Male connector M12, 5-pin Response time: ≤ 13 ms Typical range: 0 m ... 8 m Maximum demand rate: 34 /min (EN ISO 13849) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Restart interlock: + Beam coding: + Safe state in the event of a fault: At least one OSSD is in the OFF state. PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Ambient operating temperature: -20 °C ... +55 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Housing material: Aluminum alloy ALMGSI 0.5 Configuration method: Hard wired Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Synchronization: Optical, without separate synchronization Safe SICK device communication via EFI/SDL: - Housing cross-section (incl. system connection): 15 mm x 32 mm Weight: 175 g Power consumption: ≤ 3 A Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) TM (mission time): 20 a (EN ISO 13849) External device monitoring (delivery status): Deactivated Storage temperature: -25 °C ... +70 °C Cable length: 350 mm Switching current: 300 mA Switching voltage LOW: 2 V DC Conductor cross-section: 0.34 mm² Cascaded: - Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 480 mm