Specification: Part Number 1207946 Resolution: 24 mm Power consumption: ≤ 3 A External device monitoring (EDM): + Permitted cable length: ≤ 20 m Synchronization: Optical, without separate synchronization Configuration method: Hard wired Ambient operating temperature: -20 °C ... +55 °C Response time: ≤ 13 ms Typical range: 0 m ... 8 m Cable length: 350 mm Protective field height: 360 mm Automatic beam coding: + Housing cross-section (incl. system connection): 15 mm x 32 mm Weight: 135 g Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Shock resistance: 10 g, 16 ms (EN 60068-2-27) External device monitoring (delivery status): Deactivated Connection type: Male connector M12, 5-pin Test rate (internal test): 58 /s Air humidity: 15 % ... 95 %, non-condensing Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Type: Type 2 (IEC 61496) Protection class: III (EN 61140) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Cascaded: - Ripple: ≤ 10 % Switching voltage LOW: 2 V DC Storage temperature: -25 °C ... +70 °C TM (mission time): 20 a (EN ISO 13849) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Scanning range: 0 m ... 6 m Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Conductor cross-section: 0.34 mm² Restart interlock: + Beam coding: + PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Display elements: LEDs Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching current: 300 mA Enclosure rating: IP 65 (EN 60529) Housing material: Aluminum alloy ALMGSI 0.5 Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Restart interlock (delivery status): Deactivated Safe state in the event of a fault: At least one OSSD is in the OFF state. Safe SICK device communication via EFI/SDL: - Category: Category 2 (EN ISO 13849) Maximum demand rate: 34 /min (EN ISO 13849)