SICK

Image
Part Number
Description
Specification: Part Number 1207955 TM (mission time): 20 a (EN ISO 13849) Switching current: 300 mA Weight: 320 g Type: Type 2 (IEC 61496) Housing cross-section (incl. system connection): 15 mm x 32 mm External device monitoring (delivery status): Deactivated Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Ambient operating temperature: -20 °C ... +55 °C Switching voltage HIGH: 24 V DC (VS - 2.
Specification: Part Number 1207898 Cascaded: + Housing material: Aluminum alloy ALMGSI 0.5 Restart interlock: + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Beam coding: + Safe SICK device communication via EFI/SDL: - Weight: 320 g Switching voltage LOW: 2 V DC Shock resistance: 10 g, 16 ms (EN 60068-2-27) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS)
Specification: Part Number 1207937 Cable length: 700 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Shock resistance: 10 g, 16 ms (EN 60068-2-27) External device monitoring (EDM): + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Beam coding: + Resolution: 14 mm Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Safety integ
Specification: Part Number 1207880 External device monitoring (delivery status): Deactivated Air humidity: 15 % ... 95 %, non-condensing Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Restart interlock (delivery status): Deactivated Protection class: III (EN 61140) Switching voltage LOW: 2 V DC PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Permitted cable length: &l
Specification: Part Number 1207956 Enclosure rating: IP 65 (EN 60529) External device monitoring (delivery status): Deactivated Permitted cable length: ≤ 20 m Cascaded: - External device monitoring (EDM): + Typical range: 0 m ... 8 m Configuration method: Hard wired Housing cross-section (incl. system connection): 15 mm x 32 mm TM (mission time): 20 a (EN ISO 13849) Supply voltage: 24 V DC (19.2 V
Specification: Part Number 1207899 Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! External device monitoring (delivery status): Deactivated Resolution: 24 mm Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Conductor cross-section: 0.34 mm² Scanning range: 0 m
Specification: Part Number 1207975 Power consumption: ≤ 3 A External device monitoring (delivery status): Deactivated Switching current: 300 mA Enclosure rating: IP 65 (EN 60529) Resolution: 34 mm Shock resistance: 10 g, 16 ms (EN 60068-2-27) Weight: 340 g External device monitoring (EDM): + PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Configuration method: Hard wired Cable length: 700
Specification: Part Number 1207918 Connection type: Male connector M12, 5-pin Power consumption: ≤ 3 A Safe SICK device communication via EFI/SDL: - Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Beam coding: + Cable length: 700 mm External device monitoring (EDM): + Protection class: III (EN 61140) Ambient operating temperature: -20 °C ... +55 °C Integration via Flexi Soft safety cont
Specification: Part Number 1207881 Type: Type 2 (IEC 61496) Power consumption: ≤ 3 A Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Typical range: 0 m ... 8 m Restart interlock (delivery status): Deactivated Resolution: 14 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Automatic beam coding: + Housing material: Aluminum alloy ALMGSI 0.5 Connection type: Male connector M12, 5-p
Specification: Part Number 1207957 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Restart interlock: + Power consumption: ≤ 3 A Maximum demand rate: 34 /min (EN ISO 13849) External device monitoring (EDM): + PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Switching voltage LOW: 2 V DC Type: Type 2 (IEC 61496) Safe state in the event of a fault: At least one
Specification: Part Number 1207900 Enclosure rating: IP 65 (EN 60529) Scanning range: 0 m ... 6 m Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Category: Category 2 (EN ISO 13849) Restart interlock: + PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Synchronization: Optical, without separate synchronization Ambient operating temperature: -20 °C ... +55 °C Response time: ≤ 13 ms Ripple: &le
Specification: Part Number 1207958 Configuration method: Hard wired Synchronization: Optical, without separate synchronization Storage temperature: -25 °C ... +70 °C Protective field height: 1,080 mm Resolution: 24 mm Weight: 380 g Scanning range: 0 m ... 6 m Power consumption: ≤ 3 A Shock resistance: 10 g, 16 ms (EN 60068-2-27) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Air humidity:
Specification: Part Number 1207844 Resolution: 24 mm Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Beam coding: + Storage temperature: -25 °C ... +70 °C Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Maximum demand rate: 34 /min (EN ISO 13849)
Specification: Part Number 1207901 TM (mission time): 20 a (EN ISO 13849) Ripple: ≤ 10 % Restart interlock (delivery status): Deactivated Response time: ≤ 13 ms Storage temperature: -25 °C ... +70 °C Enclosure rating: IP 65 (EN 60529) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching current: 300 mA Ambient operating temperature: -20 °C ... +55 °C
Specification: Part Number 1207977 Connection type: Male connector M12, 5-pin PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Synchronization: Optical, without separate synchronization Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET External device monitoring (delivery status): Deactivated Resolution: 34 mm Cable length: 700 mm Maximum demand
Specification: Part Number 1207920 Cascaded: + Typical range: 0 m ... 8 m Permitted cable length: ≤ 20 m Switching voltage LOW: 2 V DC Cable length: 700 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Power consumption: ≤ 3 A Restart interlock (delivery status): Deactivated Automatic beam coding: + Type: Type 2 (IEC 61496) Protection class: III (EN 61140) Protective fie
Specification: Part Number 1207940 Air humidity: 15 % ... 95 %, non-condensing Cable length: 700 mm Weight: 400 g Protective field height: 1,140 mm Restart interlock (delivery status): Deactivated Response time: ≤ 17 ms Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Type: Type 2 (IEC 61496) Safe SICK device communication via EFI/SDL: - Cascaded: - Connection type: Male connector M12, 5
Specification: Part Number 1207820 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Connection type: Male connector M12, 5-pin Resolution: 14 mm Storage temperature: -25 °C ... +70 °C Cable length: 700 mm Switching voltage LOW: 2 V DC Maximum demand rate: 34 /min (EN ISO 13849) Ripple: ≤ 10 % Beam coding: + Housing material: Aluminum alloy ALMGSI 0.5 Permitted cable length: ≤ 20 m Type o
Specification: Part Number 1207883 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Housing material: Aluminum alloy ALMGSI 0.5 Type: Type 2 (IEC 61496) Ambient operating temperature: -20 °C ... +55 °C Enclosure rating: IP 65 (EN 60529) Scanning range: 0 m ... 6 m Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Performance level: PL c (EN ISO 13849), Pay attention
Specification: Part Number 1207959 Restart interlock: + Beam coding: + Ambient operating temperature: -20 °C ... +55 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Enclosure rating: IP 65 (EN 60529) Switching voltage LOW: 2 V DC Maximum demand rate: 34 /min (EN ISO 13849) Connectio
Specification: Part Number 1207845 External device monitoring (delivery status): Deactivated Enclosure rating: IP 65 (EN 60529) Response time: ≤ 13 ms Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Safe SICK device communication via EFI/SDL: - Switching current: 300 mA Configuration method: Hard wired Display elements: LEDs Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Power consumpt
Specification: Part Number 1207902 Test rate (internal test): 47 /s Connection type extension connection: Female connector M12, 5-pin Display elements: LEDs Air humidity: 15 % ... 95 %, non-condensing External device monitoring (EDM): + Safe SICK device communication via EFI/SDL: - External device monitoring (delivery status): Deactivated Automatic beam coding: + Switching current: 300 mA Switching volt
Specification: Part Number 1207978 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage LOW: 2 V DC Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Test rate (internal test): 58 /s Power consumption: ≤ 3 A Housing cross
Specification: Part Number 1207921 Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) TM (mission time): 20 a (EN ISO 13849) Synchronization: Optical, without separate synchronization Cable length: 700 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Permitted cable length: ≤ 20 m Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!
Specification: Part Number 1207960 Cascaded: - External device monitoring (EDM): + TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Response time: ≤ 13 ms Switching current: 300 mA Weight: 420 g Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protective field height: 1,200 mm Switching voltage LOW: 2 V DC Ripple: ≤ 10 % Power consumption: ≤ 3 A Typical range: 0 m ..
Specification: Part Number 1041251 Optical indicators: 6 LED Supports power supply module (CMP): No Brief description: Fieldbus proxy/gateway to connect to a PROFIBUS network Supports fieldbus gateway (CMF): Integrated (PROFIBUS DP) Shock resistance: EN 60068-2-27 (1993) Switching inputs: 2 Electromagnetic compatibility (EMC): EN 61000-6-4 (2007-01) / EN 61000-6-2:2005 PROFIBUS DP: + DeviceNet: - Scanne
Specification: Part Number 1041252 Permissible relative humidity: ± 90 %, non-condensing Electrical connection: 1 x 15-pin D Sub HD female connector (DEVICE) 12 V, max. 500 mA, 1 x 4-pin M8 female connector (AUX), 1 x 5-pin M12 female connector (PROFIBUS OUT), 1 x 5-pin M12 male connector (POWER), 1 x 5-pin M12 male connector (PROFIBUS IN), 3 x 5-pin M12 female connector (IN 1, IN 2, OUT 1/2) Brief description: CDF600 Field bus
Specification: Part Number 1048488 Enclosure rating: IP 65 (DIN 40 050) DeviceNet: - PROFIBUS DP: - Configuration software: SOPAS ET Ethernet: - Brief description: Modular connection module for one sensor, additional M12 socket for PROFINET on face plate Supports cloning module (CMC): No Switching inputs: Depending on sensor connected Serial (RS-232, RS-422/485): + Optical indicators: 4 LED (Status an
Specification: Part Number 1050643 Remark (CAN bus): Depending on sensor connected Scanner connection: 15-pin D-Sub HD socket Ambient operating temperature: -35 °C ... +40 °C Remark (Serial (RS-232, RS-422/485)): Depending on sensor connected Permissible relative humidity: ± 90 %, non-condensing Switching inputs: Depending on sensor connected Configuration software: SOPAS ET Supports power supply module (CMP
Specification: Part Number 1066272 Function (Serial (RS-232)): Host, AUX Ambient operating temperature: 0 °C ... +40 °C No. of codes per reading interval: 1 ... 50 (auto-discriminating) Front screen: Glass Data transmission rate (Serial (RS-232)): 2,400 Baud ... 115 kBaud, AUX: 57.6 kBaud CAN bus: + Enclosure rating: IP 65 (DIN 40 050) Storage temperature: -20 °C ... +70 °C Optical indicators: 1 RGB LE