Specification: Part Number 1207960 Cascaded: - External device monitoring (EDM): + TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Response time: ≤ 13 ms Switching current: 300 mA Weight: 420 g Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protective field height: 1,200 mm Switching voltage LOW: 2 V DC Ripple: ≤ 10 % Power consumption: ≤ 3 A Typical range: 0 m ... 8 m Display elements: LEDs Housing cross-section (incl. system connection): 15 mm x 32 mm Test rate (internal test): 58 /s Automatic beam coding: + PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Enclosure rating: IP 65 (EN 60529) Safe SICK device communication via EFI/SDL: - Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protection class: III (EN 61140) Permitted cable length: ≤ 20 m Maximum demand rate: 34 /min (EN ISO 13849) Cable length: 700 mm Housing material: Aluminum alloy ALMGSI 0.5 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Storage temperature: -25 °C ... +70 °C Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Restart interlock (delivery status): Deactivated Connection type: Male connector M12, 5-pin Configuration method: Hard wired External device monitoring (delivery status): Deactivated Synchronization: Optical, without separate synchronization Beam coding: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Category: Category 2 (EN ISO 13849) Scanning range: 0 m ... 6 m Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Ambient operating temperature: -20 °C ... +55 °C Shock resistance: 10 g, 16 ms (EN 60068-2-27) Air humidity: 15 % ... 95 %, non-condensing Type: Type 2 (IEC 61496) Conductor cross-section: 0.34 mm² Resolution: 24 mm