Specification: Part Number 1207978 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage LOW: 2 V DC Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Test rate (internal test): 58 /s Power consumption: ≤ 3 A Housing cross-section (incl. system connection): 15 mm x 32 mm Permitted cable length: ≤ 20 m Protection class: III (EN 61140) TM (mission time): 20 a (EN ISO 13849) Safe state in the event of a fault: At least one OSSD is in the OFF state. External device monitoring (delivery status): Deactivated Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Configuration method: Hard wired Ambient operating temperature: -20 °C ... +55 °C Connection type: Male connector M12, 5-pin Automatic beam coding: + Restart interlock (delivery status): Deactivated Conductor cross-section: 0.34 mm² Enclosure rating: IP 65 (EN 60529) Cable length: 700 mm Resolution: 34 mm Maximum demand rate: 34 /min (EN ISO 13849) External device monitoring (EDM): + Type: Type 2 (IEC 61496) Cascaded: - Scanning range: 0 m ... 6 m Response time: ≤ 13 ms Housing material: Aluminum alloy ALMGSI 0.5 PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Synchronization: Optical, without separate synchronization Protective field height: 1,140 mm Display elements: LEDs Typical range: 0 m ... 8 m Category: Category 2 (EN ISO 13849) Switching current: 300 mA Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Restart interlock: + Safe SICK device communication via EFI/SDL: - Ripple: ≤ 10 % Beam coding: + Weight: 400 g Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Storage temperature: -25 °C ... +70 °C