Specification: Part Number 1207901 TM (mission time): 20 a (EN ISO 13849) Ripple: ≤ 10 % Restart interlock (delivery status): Deactivated Response time: ≤ 13 ms Storage temperature: -25 °C ... +70 °C Enclosure rating: IP 65 (EN 60529) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching current: 300 mA Ambient operating temperature: -20 °C ... +55 °C Scanning range: 0 m ... 6 m Cascaded: + Display elements: LEDs Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Synchronization: Optical, without separate synchronization Restart interlock: + Beam coding: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Housing material: Aluminum alloy ALMGSI 0.5 Connection type extension connection: Female connector M12, 5-pin Category: Category 2 (EN ISO 13849) Safe state in the event of a fault: At least one OSSD is in the OFF state. Connection type: Male connector M12, 5-pin Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching voltage LOW: 2 V DC Safe SICK device communication via EFI/SDL: - Air humidity: 15 % ... 95 %, non-condensing Automatic beam coding: + Typical range: 0 m ... 8 m Configuration method: Hard wired Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Housing cross-section (incl. system connection): 15 mm x 32 mm Resolution: 24 mm Protective field height: 1,080 mm Cable length: 700 mm External device monitoring (EDM): + Power consumption: ≤ 3 A Weight: 380 g PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Permitted cable length: ≤ 20 m Test rate (internal test): 47 /s Type: Type 2 (IEC 61496) Conductor cross-section: 0.34 mm² Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) External device monitoring (delivery status): Deactivated Maximum demand rate: 28 /min (EN ISO 13849) Protection class: III (EN 61140)