Specification: Part Number 1207841 Response time: ≤ 13 ms Automatic beam coding: + Connection type: Male connector M12, 5-pin Weight: 320 g Scanning range: 0 m ... 6 m Configuration method: Hard wired Synchronization: Optical, without separate synchronization Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Permitted cable length: ≤ 20 m Type: Type 2 (IEC 61496) Test rate (internal test):
Specification: Part Number 1207974 Ripple: ≤ 10 % Safe state in the event of a fault: At least one OSSD is in the OFF state. Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Conductor cross-section: 0.34 mm² Restart interlock: + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Cascaded: - Automatic beam coding:
Specification: Part Number 1207860 Housing cross-section (incl. system connection): 15 mm x 32 mm Synchronization: Optical, without separate synchronization Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Restart interlock (delivery status): Deactivated Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Scanning range: 0 m ... 6 m Response time: ≤ 13 ms Protection class: I
Specification: Part Number 1207917 Switching voltage LOW: 2 V DC Scanning range: 0 m ... 6 m Response time: ≤ 13 ms Automatic beam coding: + Configuration method: Hard wired Weight: 320 g Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safe state in the event of a fault: At least one OSSD is in the OFF state. Category: Category 2 (EN ISO 13849) External device moni
Specification: Part Number 1207817 Type: Type 2 (IEC 61496) Test rate (internal test): 58 /s Permitted cable length: ≤ 20 m Restart interlock (delivery status): Deactivated External device monitoring (delivery status): Deactivated Resolution: 14 mm Maximum demand rate: 34 /min (EN ISO 13849) Beam coding: + Display elements: LEDs Safe state in the event of a fault: At least one OSSD is in the OFF s
Specification: Part Number 1207842 Air humidity: 15 % ... 95 %, non-condensing Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 960 mm Cascaded: - Housing material: Aluminum alloy ALMGSI 0.5 Conductor cross-section: 0.34 mm² Maximum demand rate: 34 /min (EN ISO 13849) Restart interlock: + Category: Category 2 (EN ISO 13849) Safety integrity level: SIL1 (IEC 61508) SI
Specification: Part Number 1207861 Category: Category 2 (EN ISO 13849) Connection type: Male connector M12, 5-pin Conductor cross-section: 0.34 mm² Ripple: ≤ 10 % Cascaded: - Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Automatic beam coding: + Scanning range: 0 m ... 6 m Housing material: Aluminum alloy ALMGSI 0.5 TM (mission time): 20 a (EN ISO 13849) Resolution: 34 mm Switching volt
Specification: Part Number 1207938 Ripple: ≤ 10 % Type: Type 2 (IEC 61496) Restart interlock: + Test rate (internal test): 58 /s Restart interlock (delivery status): Deactivated Protective field height: 1,020 mm Display elements: LEDs Cascaded: - Scanning range: 0 m ... 6 m External device monitoring (EDM): + Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Shock resistance: 10 g,
Specification: Part Number 1207818 Switching current: 300 mA Maximum demand rate: 34 /min (EN ISO 13849) Cable length: 700 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Resolution: 14 mm Category: Category 2 (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Beam coding: + Restart interlock: + Type: Type 2 (IEC 61496) Ambient operating temperature: -20 °C .
Specification: Part Number 1207843 Safe state in the event of a fault: At least one OSSD is in the OFF state. Category: Category 2 (EN ISO 13849) Synchronization: Optical, without separate synchronization External device monitoring (EDM): + Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Storage temperature: -25 °C ... +70 °C Shock resistance: 10 g, 16 ms (EN 60068-2-27) Typ
Specification: Part Number 1207976 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safe SICK device communication via EFI/SDL: - Safe state in the event of a fault: At least one OSSD is in the OFF state. Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) External device monitoring (delivery status): Deactivated Connection type: Male connector M12, 5-pin Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Specification: Part Number 1207862 Ambient operating temperature: -20 °C ... +55 °C Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Housing cross-section (incl. system connection): 15 mm x 32 mm Test rate (internal test): 58 /s Safe state in the event of a fault: At least one OSSD is in the OFF state. Automatic beam coding: + Protection class: III (EN 61140) External device
Specification: Part Number 1207919 Storage temperature: -25 °C ... +70 °C Protection class: III (EN 61140) Synchronization: Optical, without separate synchronization Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 1,020 mm Beam coding: + Enclosure rating: IP 65 (EN 60529) Response time: ≤ 13 ms Restart interlock: + Switching current: 300 mA Category: Categor
Specification: Part Number 1207939 Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Ambient operating temperature: -20 °C ... +55 °C Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Weight: 380 g Enclosure rating: IP 65 (EN 60529) Synchronization: Optical, without separate synchronization External device monitoring (delivery status): Deactivated Response time: ≤ 17 ms Configuration method:
Specification: Part Number 1207819 Safe SICK device communication via EFI/SDL: - Protection class: III (EN 61140) Test rate (internal test): 58 /s Cable length: 700 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Synchronization: Optical, without separate synchronization Restart interlock (delivery status): Deactivated Shock resistance: 10 g, 16 ms (EN 60068-2-27) Enclosure rat
Specification: Part Number 1207882 Category: Category 2 (EN ISO 13849) Beam coding: + Connection type extension connection: Female connector M12, 5-pin Safe SICK device communication via EFI/SDL: - Protective field height: 1,080 mm Restart interlock: + Switching current: 300 mA Housing material: Aluminum alloy ALMGSI 0.5 Air humidity: 15 % ... 95 %, non-condensing Housing cross-section (incl. system con
Specification: Part Number 1207863 External device monitoring (EDM): + Enclosure rating: IP 65 (EN 60529) Permitted cable length: ≤ 20 m Automatic beam coding: + Conductor cross-section: 0.34 mm² Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Resolution: 34 mm Protective field height: 1,080 mm Air humidity: 15 % ... 95 %, non-condensing Ripple: ≤ 10 % Typ
Specification: Part Number 1207864 Configuration method: Hard wired Display elements: LEDs External device monitoring (EDM): + PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Conductor cross-section: 0.34 mm² Storage temperature: -25 °C ... +70 °C Ambient operating temperature: -20 °C ... +55 °C Restart interlock: + Test rate (internal test): 58 /s Response time: ≤ 13 ms Typical range:
Specification: Part Number 1207941 Connection type: Male connector M12, 5-pin Type: Type 2 (IEC 61496) Beam coding: + Cascaded: - Switching current: 300 mA Weight: 420 g Shock resistance: 10 g, 16 ms (EN 60068-2-27) Protective field height: 1,200 mm Conductor cross-section: 0.34 mm² Typical range: 0 m ... 8 m Display elements: LEDs Housing material: Aluminum alloy ALMGSI 0.5 TM (mission tim
Specification: Part Number 1207821 Protective field height: 1,200 mm Protection class: III (EN 61140) Housing cross-section (incl. system connection): 15 mm x 32 mm Switching current: 300 mA Typical range: 0 m ... 8 m Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Response time: ≤ 17 ms Resolution: 14 mm Type: Type 2 (IEC 61496) Restart interlock (delivery status): De
Specification: Part Number 1207884 Restart interlock (delivery status): Deactivated Switching current: 300 mA Enclosure rating: IP 65 (EN 60529) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Automatic beam coding: + Scanning range: 0 m ... 6 m Protective field height: 1,200 mm Weight: 420 g Power consumption: ≤ 3 A Ripple: ≤ 10 % Air humidity: 15 % ... 95 %, non-condensing Response time:
Specification: Part Number 1207846 Display elements: LEDs Air humidity: 15 % ... 95 %, non-condensing Protective field height: 1,200 mm Conductor cross-section: 0.34 mm² Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Maximum demand rate: 34 /min (EN ISO 13849) Shock resistance: 10 g, 16 ms (EN 60068-2-27) External
Specification: Part Number 1207903 Resolution: 24 mm Scanning range: 0 m ... 6 m Permitted cable length: ≤ 20 m Storage temperature: -25 °C ... +70 °C Weight: 420 g Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Connection type extension connection: Female connector M12, 5-pin Shock resistance: 10 g, 16 ms (EN 60068-2-27) PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Cascaded: + Resta
Specification: Part Number 1207979 Restart interlock: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Category: Category 2 (EN ISO 13849) Connection type: Male connector M12, 5-pin External device monitoring (EDM): + Ambient operating temperature: -20 °C ... +55 °C Test rate (internal test): 58 /s TM (mission time): 20
Specification: Part Number 1207865 Shock resistance: 10 g, 16 ms (EN 60068-2-27) TM (mission time): 20 a (EN ISO 13849) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Beam coding: + Connection type: Male connector M12, 5-pin Cable length: 700 mm Category: Category 2 (EN ISO 13849) Permitted cable length: ≤ 20 m Scanning range: 0 m ... 6 m Conductor cross-section: 0.34 mm² Restart interlock (
Specification: Part Number 1207922 Connection type extension connection: Female connector M12, 5-pin External device monitoring (EDM): + PFHd: Cascaded systems: 5.2  1E-08 (EN ISO 13849) Conductor cross-section: 0.34 mm² TM (mission time): 20 a (EN ISO 13849) Ripple: ≤ 10 % Switching voltage LOW: 2 V DC Configuration method: Hard wired Safe SICK device communication via EFI/SDL: - Power consumpti
Specification: Part Number 1206951 Protection class: III (EN 61140) Typical range: 0 m ... 5 m Power consumption: ≤ 3 A Storage temperature: -25 °C ... +70 °C Cascaded: - Resolution: 14 mm Cable length: 160 mm Restart interlock: + Switching current: 300 mA Ripple: ≤ 10 % Safe state in the event of a fault: At least one OSSD is in the OFF state. External device monitoring (EDM): + P
Specification: Part Number 1207094 Synchronization: Optical, without separate synchronization Display elements: LEDs Beam coding: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Configuration method: Hard wired Weight: 50 g Response time: ≤ 14 ms Housing material: Aluminum alloy ALMGSI 0.5 Conductor cross-section: 0.34 mm² Category: Category 4 (EN ISO 13849) Power consumption: ≤ 3 A Vib
Specification: Part Number 1207115 Permitted cable length: ≤ 20 m Weight: 50 g Power consumption: ≤ 3 A Protection class: III (EN 61140) Air humidity: 15 % ... 95 %, non-condensing Display elements: LEDs Housing cross-section (incl. system connection): 15 mm x 32 mm External device monitoring (delivery status): Deactivated Switching current: 300 mA Safe SICK device communication via EFI/SDL: -
Specification: Part Number 1207318 Shock resistance: 10 g, 16 ms (EN 60068-2-27) PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Restart interlock: + Switching current: 300 mA Housing cross-section (incl. system connection): 15 mm x 32 mm Housing material: Aluminum alloy ALMGSI 0.5 Storage temperature: -25 °C ... +70 °C Connection type: Male connector M12, 5-pin Category: Category 4 (EN ISO 13849)