Specification: Part Number 1207860 Housing cross-section (incl. system connection): 15 mm x 32 mm Synchronization: Optical, without separate synchronization Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Restart interlock (delivery status): Deactivated Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Scanning range: 0 m ... 6 m Response time: ≤ 13 ms Protection class: III (EN 61140) External device monitoring (EDM): + Ambient operating temperature: -20 °C ... +55 °C PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Protective field height: 900 mm Power consumption: ≤ 3 A TM (mission time): 20 a (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Category: Category 2 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Connection type: Male connector M12, 5-pin Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Restart interlock: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Storage temperature: -25 °C ... +70 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored External device monitoring (delivery status): Deactivated Cable length: 700 mm Automatic beam coding: + Maximum demand rate: 34 /min (EN ISO 13849) Ripple: ≤ 10 % Housing material: Aluminum alloy ALMGSI 0.5 Typical range: 0 m ... 8 m Weight: 320 g Resolution: 34 mm Cascaded: - Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Display elements: LEDs Conductor cross-section: 0.34 mm² Configuration method: Hard wired Type: Type 2 (IEC 61496) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Permitted cable length: ≤ 20 m Safe SICK device communication via EFI/SDL: - Switching voltage LOW: 2 V DC Switching current: 300 mA Test rate (internal test): 58 /s Beam coding: +