Specification: Part Number 1207861 Category: Category 2 (EN ISO 13849) Connection type: Male connector M12, 5-pin Conductor cross-section: 0.34 mm² Ripple: ≤ 10 % Cascaded: - Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Automatic beam coding: + Scanning range: 0 m ... 6 m Housing material: Aluminum alloy ALMGSI 0.5 TM (mission time): 20 a (EN ISO 13849) Resolution: 34 mm Switching voltage LOW: 2 V DC Safe state in the event of a fault: At least one OSSD is in the OFF state. Permitted cable length: ≤ 20 m Synchronization: Optical, without separate synchronization Switching current: 300 mA Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Power consumption: ≤ 3 A Housing cross-section (incl. system connection): 15 mm x 32 mm Storage temperature: -25 °C ... +70 °C Test rate (internal test): 58 /s Safe SICK device communication via EFI/SDL: - Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Protection class: III (EN 61140) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Response time: ≤ 13 ms PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Display elements: LEDs Enclosure rating: IP 65 (EN 60529) Restart interlock: + Restart interlock (delivery status): Deactivated Weight: 340 g Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Type: Type 2 (IEC 61496) Protective field height: 960 mm External device monitoring (delivery status): Deactivated Ambient operating temperature: -20 °C ... +55 °C Typical range: 0 m ... 8 m Beam coding: + External device monitoring (EDM): + Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Air humidity: 15 % ... 95 %, non-condensing Shock resistance: 10 g, 16 ms (EN 60068-2-27) Cable length: 700 mm Maximum demand rate: 34 /min (EN ISO 13849) Configuration method: Hard wired