Specification: Part Number 1207976 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safe SICK device communication via EFI/SDL: - Safe state in the event of a fault: At least one OSSD is in the OFF state. Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) External device monitoring (delivery status): Deactivated Connection type: Male connector M12, 5-pin Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Restart interlock (delivery status): Deactivated Protective field height: 1,020 mm External device monitoring (EDM): + Test rate (internal test): 58 /s TM (mission time): 20 a (EN ISO 13849) Scanning range: 0 m ... 6 m Category: Category 2 (EN ISO 13849) Configuration method: Hard wired Typical range: 0 m ... 8 m Ambient operating temperature: -20 °C ... +55 °C Automatic beam coding: + Resolution: 34 mm Restart interlock: + Housing material: Aluminum alloy ALMGSI 0.5 Response time: ≤ 13 ms Switching current: 300 mA Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Type: Type 2 (IEC 61496) PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Synchronization: Optical, without separate synchronization Power consumption: ≤ 3 A Ripple: ≤ 10 % Weight: 360 g Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage LOW: 2 V DC Beam coding: + Enclosure rating: IP 65 (EN 60529) Cascaded: - Storage temperature: -25 °C ... +70 °C Air humidity: 15 % ... 95 %, non-condensing Permitted cable length: ≤ 20 m Conductor cross-section: 0.34 mm² Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Housing cross-section (incl. system connection): 15 mm x 32 mm Cable length: 700 mm Display elements: LEDs Protection class: III (EN 61140) Maximum demand rate: 34 /min (EN ISO 13849)