Specification: Part Number 1207919 Storage temperature: -25 °C ... +70 °C Protection class: III (EN 61140) Synchronization: Optical, without separate synchronization Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 1,020 mm Beam coding: + Enclosure rating: IP 65 (EN 60529) Response time: ≤ 13 ms Restart interlock: + Switching current: 300 mA Category: Category 2 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) TM (mission time): 20 a (EN ISO 13849) Power consumption: ≤ 3 A Permitted cable length: ≤ 20 m Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Connection type extension connection: Female connector M12, 5-pin Ambient operating temperature: -20 °C ... +55 °C Ripple: ≤ 10 % Automatic beam coding: + Safe SICK device communication via EFI/SDL: - Switching voltage LOW: 2 V DC Conductor cross-section: 0.34 mm² Maximum demand rate: 28 /min (EN ISO 13849) Restart interlock (delivery status): Deactivated Display elements: LEDs Shock resistance: 10 g, 16 ms (EN 60068-2-27) Connection type: Male connector M12, 5-pin External device monitoring (delivery status): Deactivated Air humidity: 15 % ... 95 %, non-condensing Test rate (internal test): 47 /s PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing cross-section (incl. system connection): 15 mm x 32 mm Typical range: 0 m ... 8 m Resolution: 34 mm Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Cable length: 700 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Weight: 360 g Housing material: Aluminum alloy ALMGSI 0.5 Configuration method: Hard wired External device monitoring (EDM): + Scanning range: 0 m ... 6 m Type: Type 2 (IEC 61496) Cascaded: +