Specification: Part Number 1207821 Protective field height: 1,200 mm Protection class: III (EN 61140) Housing cross-section (incl. system connection): 15 mm x 32 mm Switching current: 300 mA Typical range: 0 m ... 8 m Ambient operating temperature: -20 °C ... +55 °C Display elements: LEDs Response time: ≤ 17 ms Resolution: 14 mm Type: Type 2 (IEC 61496) Restart interlock (delivery status): Deactivated Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Permitted cable length: ≤ 20 m Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored External device monitoring (delivery status): Deactivated Cascaded: - Safe state in the event of a fault: At least one OSSD is in the OFF state. Safe SICK device communication via EFI/SDL: - Maximum demand rate: 34 /min (EN ISO 13849) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Housing material: Aluminum alloy ALMGSI 0.5 Test rate (internal test): 58 /s Ripple: ≤ 10 % Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) External device monitoring (EDM): + Restart interlock: + Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) Storage temperature: -25 °C ... +70 °C Enclosure rating: IP 65 (EN 60529) Air humidity: 15 % ... 95 %, non-condensing PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Beam coding: + Scanning range: 0 m ... 6 m Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Automatic beam coding: + Weight: 420 g Configuration method: Hard wired Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Category: Category 2 (EN ISO 13849) Cable length: 700 mm Power consumption: ≤ 3 A Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Switching voltage LOW: 2 V DC Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Synchronization: Optical, without separate synchronization Conductor cross-section: 0.34 mm²