Specification: Part Number 1207222 Enclosure rating: IP 65 (EN 60529) Scanning range: 0 m ... 4 m Beam coding: + Display elements: LEDs Type: Type 4 (IEC 61496) Safe SICK device communication via EFI/SDL: - Ripple: ≤ 10 % Housing cross-section (incl. system connection): 15 mm x 32 mm External device monitoring (delivery status): Deactivated Safe state in the event of a fault: At least one OSSD is i
Specification: Part Number 1207168 Restart interlock (delivery status): Deactivated Housing material: Aluminum alloy ALMGSI 0.5 Performance level: PL e (EN ISO 13849) Cable length: 160 mm Configuration method: Hard wired Beam coding: + Switching current: 300 mA Ambient operating temperature: -20 °C ... +55 °C Housing cross-section (incl. system connection): 15 mm x 32 mm Shock resistance: 10 g, 16 ms
Specification: Part Number 1207334 Housing cross-section (incl. system connection): 15 mm x 32 mm Protective field height: 120 mm PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Typical range: 0 m ... 5 m Scanning range: 0 m ... 4 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Resolution: 34 mm Air humidity: 15 % ... 95 %, no
Specification: Part Number 1207242 Cable length: 160 mm Protective field height: 120 mm PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Resolution: 34 mm Type: Type 4 (IEC 61496) Safe SICK device communication via EFI/SDL: - Permitted cable length: ≤ 20 m Connection type: Male connector M12, 5-pin Conductor cross-section: 0.34 mm² Scanning range: 0 m ... 4 m Supply voltage: 24 V DC (19.2
Specification: Part Number 1207300 Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching current: 300 mA Display elements: LEDs Cable length: 160 mm Beam coding: + Power consumption: ≤ 3 A Switching voltage LOW: 2 V DC Performance level: PL e (EN ISO 13849) TM (mission time):
Specification: Part Number 1206945 PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Typical range: 0 m ... 5 m Weight: 75 g Performance level: PL e (EN ISO 13849) Conductor cross-section: 0.34 mm² Response time: ≤ 14 ms Shock resistance: 10 g, 16 ms (EN 60068-2-27) Type of output: PNP semiconductors, short-circuit protected, cross-circuit
Specification: Part Number 1207097 Shock resistance: 10 g, 16 ms (EN 60068-2-27) External device monitoring (EDM): + Protection class: III (EN 61140) Type: Type 4 (IEC 61496) Cable length: 160 mm Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Conductor cross-section: 0.34 mm² Safe SICK device communication via EFI/SDL: - Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) External device moni
Specification: Part Number 1207116 Connection type extension connection: Female connector M12, 5-pin Cascaded: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Synchronization: Optical, without separate synchronization Conductor cross-section: 0.34 mm² Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Ripple: ≤ 10 % Configuration method: Hard wired External device monitoring (delivery
Specification: Part Number 1207177 Housing material: Aluminum alloy ALMGSI 0.5 PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Storage temperature: -25 °C ... +70 °C Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protection class: III (EN 61140) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Enclosure rating: IP 65 (EN 60529) Configuration method: Hard wired
Specification: Part Number 1207223 Storage temperature: -25 °C ... +70 °C External device monitoring (delivery status): Deactivated Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Synchronization: Optical, without separate synchronization Connection type: Male connector M12, 5-pin Safe state in the event of a fault: At least one OSSD is in the OFF state. Scanning range: 0 m ... 4 m Type: Type 4 (IEC
Specification: Part Number 1207283 Power consumption: ≤ 3 A Category: Category 4 (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm Connection type: Male connector M12, 5-pin Restart interlock: + Conductor cross-section: 0.34 mm² Shock resistance: 10 g, 16 ms (EN 60068-2-27) Beam coding: + Typical range: 0 m ... 5 m Ripple: ≤ 10 % Weight: 75 g Switching curren
Specification: Part Number 1207335 Air humidity: 15 % ... 95 %, non-condensing Scanning range: 0 m ... 4 m Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Cable length: 160 mm Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Ripple: ≤ 10 % Protection class: III (EN 61140) Dis
Specification: Part Number 1207243 Storage temperature: -25 °C ... +70 °C Response time: ≤ 13 ms Permitted cable length: ≤ 20 m Restart interlock (delivery status): Deactivated Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Safe SICK device communication via EFI/SDL: - Ambient operating temperature: -20 °C ... +55 °C Conductor
Specification: Part Number 1207301 Protective field height: 180 mm Switching voltage LOW: 2 V DC Safe state in the event of a fault: At least one OSSD is in the OFF state. Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Cascaded: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Synchronization: Optical, without separate synchronization Permitted cable
Specification: Part Number 1206954 Ripple: ≤ 10 % Beam coding: + Weight: 95 g Conductor cross-section: 0.34 mm² External device monitoring (delivery status): Deactivated Housing material: Aluminum alloy ALMGSI 0.5 Protective field height: 240 mm Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Response time: ≤ 14 ms PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Safe state in the eve
Specification: Part Number 1207098 Restart interlock: + Display elements: LEDs Conductor cross-section: 0.34 mm² Safe SICK device communication via EFI/SDL: - External device monitoring (delivery status): Deactivated Housing cross-section (incl. system connection): 15 mm x 32 mm Category: Category 4 (EN ISO 13849) Protective field height: 240 mm Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) S
Specification: Part Number 1207117 Air humidity: 15 % ... 95 %, non-condensing Typical range: 0 m ... 5 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 240 mm Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Enclosure rating: IP 65 (EN 60529) Automatic beam coding: + Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Safe SICK device communication via EFI/SDL: -
Specification: Part Number 1207319 Safe state in the event of a fault: At least one OSSD is in the OFF state. Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Beam coding: + Switching voltage LOW: 2 V DC Synchronization: Optical, without separate synchronization Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching voltage HIGH: 24 V DC (
Specification: Part Number 1207224 Ambient operating temperature: -20 °C ... +55 °C Power consumption: ≤ 3 A Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Housing material: Aluminum alloy ALMGSI 0.5 Beam coding: + Resolution: 24 mm Weight: 95 g Typical range: 0 m ... 5 m Storage temperature: -25 °C ... +70 °C Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPM
Specification: Part Number 1207284 Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Beam coding: + Synchronization: Optical, without separate synchronization Cascaded: + Type: Type 4 (IEC 61496) Category: Category 4 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) External device monitoring (delivery status): Deactivated Response time: ≤ 13 ms Automatic beam coding:
Specification: Part Number 1207336 Weight: 95 g Automatic beam coding: + Performance level: PL e (EN ISO 13849) Category: Category 4 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Power consumption: ≤ 3 A External device monitoring (EDM): + External device monitoring (delivery status): Deactivated Integra
Specification: Part Number 1207244 Switching current: 300 mA Typical range: 0 m ... 5 m Protective field height: 240 mm Type: Type 4 (IEC 61496) PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Cable length: 350 mm Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Housing cross-section (incl. system connection): 15 mm x 32 mm Conductor cross-section: 0.34 mm² Response time: ≤ 13 ms Sc
Specification: Part Number 1207302 Performance level: PL e (EN ISO 13849) Configuration method: Hard wired Protection class: III (EN 61140) Safe SICK device communication via EFI/SDL: - Weight: 95 g Air humidity: 15 % ... 95 %, non-condensing Cable length: 350 mm Restart interlock (delivery status): Deactivated Connection type extension connection: Female connector M12, 5-pin External device monitoring
Specification: Part Number 1206953 Housing cross-section (incl. system connection): 15 mm x 32 mm Beam coding: + Automatic beam coding: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Protective field height: 300 mm Enclosure rating: IP 65 (EN 60529) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Performance level: PL e (EN ISO 13849) Typical range: 0 m ... 5 m Wei
Specification: Part Number 1207099 Restart interlock: + Resolution: 14 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Connection type: Male connector M12, 5-pin Storage temperature: -25 °C ... +70 °C External device monitoring (delivery status): Deactivated Enclosure rating: IP 65 (EN 60529) Protective field height: 300 mm Type: Type 4 (IEC 61496) Housing cross-section (
Specification: Part Number 1207118 Performance level: PL e (EN ISO 13849) Safe SICK device communication via EFI/SDL: - Beam coding: + Configuration method: Hard wired Housing material: Aluminum alloy ALMGSI 0.5 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Integration via
Specification: Part Number 1207320 Restart interlock (delivery status): Deactivated Connection type: Male connector M12, 5-pin Category: Category 4 (EN ISO 13849) PFHd: Standalone system: 4.3  1E-09 (EN ISO 13849) Switching current: 300 mA Permitted cable length: ≤ 20 m Beam coding: + Enclosure rating: IP 65 (EN 60529) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Ambient operating temperature
Specification: Part Number 1207225 TM (mission time): 20 a (EN ISO 13849) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) External device monitoring (delivery status): Deactivated Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Category: Category 4 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Conductor cross-section: 0.34 mm² Safe SICK device commu
Specification: Part Number 1207285 Protection class: III (EN 61140) Connection type: Male connector M12, 5-pin Housing material: Aluminum alloy ALMGSI 0.5 Scanning range: 0 m ... 4 m PFHd: Cascaded systems: 1.3  1E-08 (EN ISO 13849) Power consumption: ≤ 3 A Cascaded: + External device monitoring (delivery status): Deactivated Beam coding: + Integration via Flexi Soft safety controller: CANopenDev
Specification: Part Number 1207337 Performance level: PL e (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Permitted cable length: ≤ 20 m Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Safe state in the event of a fault: At least one OSSD is in the OFF state. Cascaded: - Ripple: ≤ 10 % Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Restart interlock: + Housing cro