Specification: Part Number 1207336 Weight: 95 g Automatic beam coding: + Performance level: PL e (EN ISO 13849) Category: Category 4 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Power consumption: ≤ 3 A External device monitoring (EDM): + External device monitoring (delivery status): Deactivated Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Display elements: LEDs Cable length: 350 mm Protective field height: 240 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Response time: ≤ 13 ms Safe SICK device communication via EFI/SDL: - Housing cross-section (incl. system connection): 15 mm x 32 mm Configuration method: Hard wired Connection type: Male connector M12, 5-pin Restart interlock (delivery status): Deactivated Synchronization: Optical, without separate synchronization Switching current: 300 mA PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Resolution: 34 mm Permitted cable length: ≤ 20 m Conductor cross-section: 0.34 mm² Shock resistance: 10 g, 16 ms (EN 60068-2-27) Ripple: ≤ 10 % Beam coding: + Restart interlock: + Type: Type 4 (IEC 61496) Protection class: III (EN 61140) Switching voltage LOW: 2 V DC Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Typical range: 0 m ... 5 m Storage temperature: -25 °C ... +70 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Cascaded: - Scanning range: 0 m ... 4 m Housing material: Aluminum alloy ALMGSI 0.5 Air humidity: 15 % ... 95 %, non-condensing Ambient operating temperature: -20 °C ... +55 °C