Specification: Part Number 1207222 Enclosure rating: IP 65 (EN 60529) Scanning range: 0 m ... 4 m Beam coding: + Display elements: LEDs Type: Type 4 (IEC 61496) Safe SICK device communication via EFI/SDL: - Ripple: ≤ 10 % Housing cross-section (incl. system connection): 15 mm x 32 mm External device monitoring (delivery status): Deactivated Safe state in the event of a fault: At least one OSSD is in the OFF state. Typical range: 0 m ... 5 m Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Storage temperature: -25 °C ... +70 °C External device monitoring (EDM): + Switching voltage LOW: 2 V DC Automatic beam coding: + Switching current: 300 mA TM (mission time): 20 a (EN ISO 13849) Permitted cable length: ≤ 20 m PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Category: Category 4 (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Weight: 50 g Connection type: Male connector M12, 5-pin Protective field height: 120 mm Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Response time: ≤ 13 ms Performance level: PL e (EN ISO 13849) Restart interlock: + Power consumption: ≤ 3 A Synchronization: Optical, without separate synchronization Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Conductor cross-section: 0.34 mm² Ambient operating temperature: -20 °C ... +55 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Configuration method: Hard wired Housing material: Aluminum alloy ALMGSI 0.5 Resolution: 24 mm Protection class: III (EN 61140) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Cascaded: - Restart interlock (delivery status): Deactivated Cable length: 160 mm Air humidity: 15 % ... 95 %, non-condensing