Specification: Part Number 1207116 Connection type extension connection: Female connector M12, 5-pin Cascaded: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Synchronization: Optical, without separate synchronization Conductor cross-section: 0.34 mm² Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Ripple: ≤ 10 % Configuration method: Hard wired External device monitoring (delivery status): Deactivated Protective field height: 180 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Cable length: 160 mm Restart interlock (delivery status): Deactivated Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Switching voltage LOW: 2 V DC Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Restart interlock: + Category: Category 4 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) External device monitoring (EDM): + Housing cross-section (incl. system connection): 15 mm x 32 mm Resolution: 14 mm PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Display elements: LEDs Performance level: PL e (EN ISO 13849) Connection type: Male connector M12, 5-pin Scanning range: 0 m ... 4 m Permitted cable length: ≤ 20 m Automatic beam coding: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Housing material: Aluminum alloy ALMGSI 0.5 Typical range: 0 m ... 5 m Safe state in the event of a fault: At least one OSSD is in the OFF state. Safe SICK device communication via EFI/SDL: - Weight: 75 g Protection class: III (EN 61140) Beam coding: + Power consumption: ≤ 3 A Air humidity: 15 % ... 95 %, non-condensing Ambient operating temperature: -20 °C ... +55 °C Switching current: 300 mA Shock resistance: 10 g, 16 ms (EN 60068-2-27) Type: Type 4 (IEC 61496) TM (mission time): 20 a (EN ISO 13849) Storage temperature: -25 °C ... +70 °C Response time: ≤ 14 ms