Materials Housing: aluminium die-cast Flange: aluminium Weight approx. 300 g Reference signal Zero pulse, width 90° ±10 % Protection DIN EN 60529 IP 65 Approval UL 508 / CSA 22.2 Interference immunity DIN EN 61000-6-2 Shaft type ø8...15 mm (blind hollow shaft) Scan ratio 40...60 % Reverse polarity protection Yes Motor shaft tolerance 0.2 mm axial 0.03 mm radial Resistance DIN
Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 300 g, 6 ms Sensing method Optical Size (flange) ø58 mm Connection Flange connector M12, 8-pin Flange connector M23, 12-pin Cable Emitted interference DIN EN 61000-6-3 Phase shift 90° ±10° Scan ratio 40...60 % Shaft type ø10 x 20 mm, solid shaft with flat (clamping flange) Operating speed ≤12000 rp
Protection DIN EN 60529 IP 66 Approvals CE UL approval / E256710 Output frequency ≤120 kHz ≤300 kHz (on request) Admitted shaft load ≤200 N axial ≤300 N radial Reference signal Zero pulse, width 90° Weight approx. 700 g Interference immunity EN 61000-6-2 FOG 9 output signals K1, K2, K0 + inverted Error output (only EMS) Emitted interference EN 61000-6-3 Rotor moment of inertia 1
Rotor moment of inertia 160 gcm² Open-circuit voltage 10...30 mV per rpm Armature-circuit time-constant Calibration tolerance ±5 % Operating speed ≤10000 rpm Isolation class B Reversal tolerance ≤0.1 % Weight approx. 1.3 kg Consumption w/o load ≤100 mA Emitted interference EN 61000-6-3 Scan ratio 40...60 % Operating temperature -30...+100 °C -25...+100 °C (>3072
Scan ratio 40...60 % Flange EURO flange B10 Admitted shaft load ≤200 N axial ≤300 N radial Linearity tolerance ≤0.15 % Rotor moment of inertia 160 gcm² Reference signal Zero pulse, width 90° Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms Isolation class B Shaft type ø11 mm solid shaft manufacter SKU FOG 9 + GT 7.16 Materials H
Protection DIN EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Operating speed ≤10000 rpm Reference signal Zero pulse, width 90° Approval UL approval / E63076 Emitted interference DIN EN 61000-6-4 Sensing method Optical Interference immunity DIN EN 61000-6-2 Weight approx. 250 g Starting torque ≤0.015 Nm (IP 54) ≤0.03 Nm (IP 65) Rotor moment of inertia 20 gcm²
Rotor moment of inertia 20 gcm² Interference immunity DIN EN 61000-6-2 Output stages Linedriver/RS422 Push-pull short-circuit proof Admitted shaft load ≤20 N axial ≤40 N radial Reference signal Zero pulse, width 90° Protection DIN EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Voltage supply 5 VDC ±10 % 4.75...30 VDC 10...30 VDC manufacter SKU G0356 Approval UL approval / E
Rotor moment of inertia 20 gcm² Steps per turn ≤16384 / 14 bit Materials Housing: aluminium Flange: aluminium Output stages SSI data: linedriver RS485 Diagnostic and incremental outputs Operating temperature -25...+85 °C -40...+85 °C (optional) Approval UL approval / E63076 Size (flange) ø58 mm Code Gray or binary Function Singleturn Sensing method Optical Shaft type &
Steps per turn ≤16384 / 14 bit Code Gray or binary Interference immunity DIN EN 61000-6-2 Operating temperature -25...+85 °C -40...+85 °C (optional) manufacter SKU G0M2H Starting acceleration ≤1000 U/s² Number of turns 4096 / 12 bit Initializing time typ. 20 ms after power on Function Multiturn Code sequence CW/CCW coded by connection Voltage supply 10...30 VDC Approval
Rotor moment of inertia 2000 gcm² Connection Connector M23, 12-pin Reference signal Zero pulse, width 90° Operating temperature -25...+85 °C (24 VDC) -40...+85 °C (optional) Size (flange) ø75 mm Operating speed ≤3800 rpm manufacter SKU G1I0S Weight approx. 700 g Shaft type ø20 mm (blind hollow shaft) ø25 mm (blind hollow shaft) Materials Housing: aluminium Flang
Inputs SSI clock Control signals UP/ DOWN and zero Shaft type ø25.4 mm (through hollow shaft) Consumption w/o load ≤50 mA (24 VDC) Size (flange) ø90 mm Function Multiturn Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Absolute accuracy ±0.025 ° Diagnostic functions Self-diagnosis Multiturn sensing manufacter SKU G1M2H Relative hum
Emitted interference DIN EN 61000-6-4 Approval UL approval / E63076 Operating speed ≤3800 rpm (mechanical) ≤6000 rpm (electric) Weight approx. 890 g Consumption w/o load ≤100 mA (24 VDC) Code sequence CW/CCW programmable Initializing time typ. 250 ms after power on manufacter SKU G1MMH Status indicator DUO-LED integrated in bus cover Reverse polarity protection Yes Function Mult
Materials Housing: aluminium Flange: aluminium Approval UL approval / E63076 Operating temperature -25...+85 °C Diagnostic functions Self-diagnosis Multiturn sensing Voltage supply 10...30 VDC Inputs SSI clock Control signals UP/ DOWN and zero Output stages SSI data: linedriver RS485 Diagnostic outputs push-pull Rotor moment of inertia 11000 gcm² Resistance DIN EN 60068-2-6 Vibration 10 g,
Operating temperature -25...+85 °C -40...+85 °C (optional) Emitted interference DIN EN 61000-6-4 Weight approx. 1200 g Sensing method Optical Function Multiturn Rotor moment of inertia 11000 gcm² Materials Housing: aluminium Flange: aluminium Bus cover: aluminium Connection Bus cover Status indicator DUO-LED integrated in bus cover Starting torque ≤0.5 Nm Device adress Rotary
Operating speed ≤10000 rpm (mechanical) ≤6000 rpm (electric) Protection DIN EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Emitted interference DIN EN 61000-6-4 Approval UL approval / E63076 Size (flange) ø58 mm Output stages Push-pull short-circuit proof Relative humidity 95 % non-condensing Function Singleturn Shaft type ø10 mm solid shaft Consumption w/o loa
Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Sensing method Optical Interference immunity DIN EN 61000-6-2 Weight approx. 250 g Initializing time typ. 20 ms after power on Emitted interference DIN EN 61000-6-4 Inputs Control signals UP/ DOWN and zero STORE ENABLE Relative humidity 95 % non-condensing Voltage supply 10...30 VDC Rotor moment o
Weight approx. 250 g Interference immunity DIN EN 61000-6-2 Code Gray or binary Output stages SSI data: linedriver RS485 Diagnostic outputs push-pull Incremental: push-pull or linedriver RS422 Function Singleturn Consumption w/o load ≤50 mA (24 VDC) Inputs SSI clock Control signals UP/ DOWN and zero Voltage supply 10...30 VDC Operating speed ≤10000 rpm (mechanical) ≤6000 rpm (electric)
Flange Synchro flange manufacter SKU GA241 - parallel Function Singleturn Initializing time typ. 20 ms after power on Approval UL approval / E63076 Interference immunity DIN EN 61000-6-2 Voltage supply 10...30 VDC Relative humidity 95 % non-condensing Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Protection DIN EN 60529 IP 54 (without shaft seal)
Inputs SSI clock Control signals UP/ DOWN and zero Interfaces SSI Incremental A 90° B (optional) Steps per turn ≤262144 / 18 bit Materials Housing: aluminium Flange: aluminium Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Rotor moment of inertia 20 gcm² Operating speed ≤6000 rpm (mechanical) ≤6000 rpm (electric) Incremental output 2048 pulse