Emitted interference DIN EN 61000-6-4 Approval UL approval / E63076 Operating speed ≤3800 rpm (mechanical) ≤6000 rpm (electric) Weight approx. 890 g Consumption w/o load ≤100 mA (24 VDC) Code sequence CW/CCW programmable Initializing time typ. 250 ms after power on manufacter SKU G1MMH Status indicator DUO-LED integrated in bus cover Reverse polarity protection Yes Function Multiturn Steps per turn ≤8192 / 13 bit Diagnostic functions Position or parameter error Multiturn sensing Starting torque ≤0.35 Nm Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Connection Bus cover Shaft type ø16...25.4 mm (through hollow shaft) Relative humidity 95 % non-condensing Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Interference immunity DIN EN 61000-6-2 Sensing method Optical Protection DIN EN 60529 IP 54 IP 65 (optional) Voltage supply 10...30 VDC Device adress Rotary switch in bus cover Size (flange) ø90 mm Rotor moment of inertia 2000 gcm² Materials Housing: aluminium Flange: aluminium Bus cover: aluminium Absolute accuracy ±0.025 ° Operating temperature -25...+85 °C -40...+85 °C (optional) Interfaces CANopen® DeviceNet Profibus-DPV0 Number of turns ≤65536 / 16 bit Code Binary