Operating temperature -25...+85 °C -40...+85 °C (optional) Emitted interference DIN EN 61000-6-4 Weight approx. 1200 g Sensing method Optical Function Multiturn Rotor moment of inertia 11000 gcm² Materials Housing: aluminium Flange: aluminium Bus cover: aluminium Connection Bus cover Status indicator DUO-LED integrated in bus cover Starting torque ≤0.5 Nm Device adress Rotary switch in bus cover Number of turns ≤65536 / 16 bit Operating speed ≤2000 rpm (mechanical) ≤6000 rpm (electric) Code sequence CW/CCW programmable Shaft type ø50.8 mm (through hollow shaft) Approval UL approval / E63076 Reverse polarity protection Yes Steps per turn ≤8192 / 13 bit Relative humidity 95 % non-condensing manufacter SKU G2MMH Protection DIN EN 60529 IP 54 IP 65 (optional) Initializing time typ. 250 ms after power on Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Voltage supply 10...30 VDC Code Binary Consumption w/o load ≤100 mA (24 VDC) Absolute accuracy ±0.025 ° Interfaces CANopen® DeviceNet Profibus-DPV0 Interference immunity DIN EN 61000-6-2 Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Size (flange) ø116 mm Diagnostic functions Position or parameter error Multiturn sensing