Specification: Part Number 1028934 Data interface: RS-422 Distance measuring range: 49 m Expanded measured data output (CMS): - Protection class: II (EN 50178) Ambient operating temperature: -10 °C ... +50 °C Number of reset-/restart inputs: 1 Weight: 3.3 kg Maximum output current: 500 mA Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Specification: Part Number 1028935 Maximum output current: 500 mA Number of field sets: 4 Number of simultaneously monitored protective fields: ≤ 4 External device monitoring (EDM): + Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Number of EDM inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Hazardous area protection (vertical): + Safe SICK device communication via EFI/SDL: + Protect
Specification: Part Number 1028938 PFHd: 8.0 1E-08 (EN ISO 13849) Maximum warning field range: 49 m Access protection (vertical): + Number of application diagnostic outputs: 3 Category: Category 3 (EN ISO 13849) Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Measured data output: + Number of multiple samplings: Configurable 2 ... 16 Hazardous area protection (horizontal): + Expanded meas
Specification: Part Number 1052591 Type of field set: Dual field sets Number of simultaneously monitored protective fields: 2 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) TM (mission time): 20 a (EN ISO 13849) External device monitoring (EDM): - Response time: 60 ms Type: Type 3 (IEC 61496) Port properties: Auto-negotiation Auto-c
Specification: Part Number 1045650 Hazardous area protection (horizontal): + Number of multiple samplings: Configurable 2 ... 16 Performance level: PL d (EN ISO 13849) Incremental encoder inputs: - Conformance: Conformance Class B Safe SICK device communication via EFI/SDL: - Maximum warning field range: 49 m Access protection (vertical): + Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Dia
Specification: Part Number 1052592 Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer D
Specification: Part Number 1045651 Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. Incremental encoder inputs: - Functio
Specification: Part Number 1023546 TM (mission time): 20 a (EN ISO 13849) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Distance measuring range: 49 m Hazardous area protection (vertical): + Static protective field switching: - Ambient operating temperature: -10 °C ... +50 °C Integrated configuration memory: + Category: Category 3 (EN ISO 13849) Configuration and diagnostics interface: RS-232 PFHd:
Specification: Part Number 1023547 Number of static control inputs: 2 Number of EDM inputs: 1 Configuration and diagnostics interface: RS-232 PFHd: 8.0 1E-08 (EN ISO 13849) Static protective field switching: + Number of field sets: 4 Maximum warning field range: 49 m Safe SICK device communication via EFI/SDL: + Protection class: II (EN 50178) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Safety
Specification: Part Number 1019600 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) External device monitoring (EDM): + Number of multiple samplings: Configurable 2 ... 16 Electrical connection: System plug with or without connecting cable Distance measuring range: 49 m Protection class: II (EN 50178) PFHd: 8.0 1E-08 (EN ISO 13849) Measured data output: + Access protection (vertical): + Weig
Specification: Part Number 1023548 Electrical connection: System plug with or without connecting cable Configuration and diagnostics interface: RS-232 Protective field range: 5.5 m Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Number of monitoring cases: 32 Number of multiple samplings: Configurable 2 ... 16 Weight: 3.3 kg Data interface: RS-4
Specification: Part Number 1052593 Measured data output: + Type of field set: Dual field sets Number of simultaneously monitored protective fields: 2 Expanded measured data output (CMS): - Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Number of field sets: 4 Safe SICK device communication via EFI/SDL: - Electrical connection: Optical fiber conductor (2 female connectors for SCRJ pus
Specification: Part Number 1045652 Enclosure rating: IP 65 (EN 60529) Hazardous area protection (horizontal): + Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Configuration and diagnostics interface: RS-232 External device monitoring (EDM): - PFHd: 8.0 1E-08 (EN ISO 13849) Response time: 60 ms Conformance: Conformance Class B Functions that are not supported: Multicast communication Super
Specification: Part Number 1052594 Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer A
Specification: Part Number 1045653 Incremental encoder inputs: - Weight: 3.3 kg Response time: 60 ms Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Maximum warning field range: 49 m Hazardous area protection (horizontal): + Expanded measured data output (CMS): - Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network p
Specification: Part Number 1023890 Safe SICK device communication via EFI/SDL: + Maximum output current: 500 mA Number of simultaneously monitored protective fields: ≤ 4 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Integrated configuration memory: + Distance measuring range: 49 m Performance level: PL d (EN ISO 13849) Maximum warning field range: 49 m Scan angle: 190 ° Configuration
Specification: Part Number 1023891 Expanded measured data output (CMS): - Hazardous area protection (horizontal): + Type: Type 3 (IEC 61496) Distance measuring range: 49 m Hazardous area protection (vertical): + Ambient operating temperature: -10 °C ... +50 °C Number of reset-/restart inputs: 1 Type of field set: Dual field sets, Triple field sets Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:
Specification: Part Number 1023892 Access protection (vertical): + Number of multiple samplings: Configurable 2 ... 16 Scan angle: 190 ° Expanded measured data output (CMS): - TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 16 Number of dynamic control inputs: 2 External device monitoring (EDM): + Incremental encoder inputs: + Number of application diagnostic outputs: 3 Electri
Specification: Part Number 1023893 Number of EDM inputs: 1 PFHd: 8.0 1E-08 (EN ISO 13849) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Performance level: PL d (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Protection class: II (EN 50178) Maximum warning field range: 49 m Number of multiple samplings: Configurable 2 ... 16 Number of static control inputs with EFI: 5
Specification: Part Number 1052109 Number of multiple samplings: Configurable 2 ... 16 Maximum output current: 500 mA Number of monitoring cases: 32 Response time: 60 ms Access protection (vertical): + Scan angle: 190 ° Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Protection class: II (EN 50178) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Static protective field switching: +
Specification: Part Number 1052595 Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Hazardous area protection (vertical): + Number of monitoring cases: 4 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Distance measuring range: 49 m Weight: 3.3 kg Type of field set: Dual field sets PFHd: 8.0 1E-08 (
Specification: Part Number 1045654 Distance measuring range: 49 m Number of field sets: 4 Number of multiple samplings: Configurable 2 ... 16 Performance level: PL d (EN ISO 13849) Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Access protection (vertical): + Integrated configuration memory: + Conformance: Conformance Class B Scan angle: 190 ° Hazardous area protection
Specification: Part Number 1052596 Access protection (vertical): + Scan angle: 190 ° Number of simultaneously monitored protective fields: 2 Hazardous area protection (horizontal): + Category: Category 3 (EN ISO 13849) External device monitoring (EDM): - Weight: 3.3 kg Hazardous area protection (vertical): + Number of monitoring cases: 16 Incremental encoder inputs: - Configuration and diagnostics
Specification: Part Number 1045655 Safe SICK device communication via EFI/SDL: - Maximum warning field range: 49 m Number of multiple samplings: Configurable 2 ... 16 Protective field range: 7 m Conformance: Conformance Class B Weight: 3.3 kg Integrated configuration memory: + Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Switch properties: F
Specification: Part Number 1026820 Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Number of field sets: 1 Hazardous area protection (horizontal): + Number of safe outputs: 2, Safety outputs (OSSD) Response time: 80 ms Type: Type 3 (IEC 61496) Type of field set: Triple field sets Maximum warning field range: 8 m Category: Category 3 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Number of multiple s
Specification: Part Number 1026821 Integrated configuration memory: + Configuration and diagnostics interface: RS-232 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Expanded measured data output (CMS): - Number of stand-by inputs: 1 Static protective field switching: + Ambient operating temperature: -10 °C ... +50 °C Type: Type 3 (IEC 61496) Category: Category 3 (EN ISO 13849) Scan ang
Specification: Part Number 1026822 Electrical connection: System plug with or without connecting cable Ambient operating temperature: -10 °C ... +50 °C Number of field sets: 8 Number of EDM inputs: 1 Dimensions (W x H x D): 102 mm x 152 mm x 106 mm PFHd: 8.0 1E-08 (EN ISO 13849) Number of dynamic control inputs: 2 Distance measuring range: 30 m Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:
Specification: Part Number 1050193 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Number of EDM inputs: 1 Safe SICK device communication via EFI/SDL: + Number of stand-by inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Access protection (vertical): + Data interface: RS-422 Enclosure rating: IP 65 (EN 60529) Response time: 80 ms Integrated configuration memory: + PFHd: 8.0 1E-
Specification: Part Number 1056427 Incremental encoder inputs: - Number of reset-/restart inputs: 1 Hazardous area protection (vertical): + Type: Type 3 (IEC 61496) Integrated configuration memory: + Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Safe SICK device communication via EFI/SDL: + TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 1 Static protective field switching: - Dimen