S30A-6111DL

Specification: Part Number 1052594 Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer Access protection (vertical): + Static protective field switching: + Protection class: III (VDE 0106, EN 60950) Number of field sets: 8 Distance measuring range: 49 m Hazardous area protection (vertical): + Type: Type 3 (IEC 61496) Performance level: PL d (EN ISO 13849) Safe SICK device communication via EFI/SDL: - Integrated configuration memory: + Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Hazardous area protection (horizontal): + External device monitoring (EDM): - Number of multiple samplings: Configurable 2 ... 16 Protective field range: 5.5 m Expanded measured data output (CMS): - Weight: 3.3 kg Category: Category 3 (EN ISO 13849) Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Response time: 60 ms Functions that are not supported: Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-FX Conformance: Conformance Class B Incremental encoder inputs: - Enclosure rating: IP 65 (EN 60529) PFHd: 8.0 1E-08 (EN ISO 13849) Type of field set: Dual field sets Dimensions (W x H x D): 155 mm x 185 mm x 160 mm TM (mission time): 20 a (EN ISO 13849) Measured data output: + Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Scan angle: 190 ° Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Maintenance alerts for POF interfaces for signal quality Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 Ambient operating temperature: -10 °C ... +50 °C Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Electrical connection: Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Number of simultaneously monitored protective fields: 2 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Maximum warning field range: 49 m Number of monitoring cases: 16 Configuration and diagnostics interface: RS-232
Part Number S30A-6111DL
Manufacture SICK
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com