Specification: Part Number 1023892 Access protection (vertical): + Number of multiple samplings: Configurable 2 ... 16 Scan angle: 190 ° Expanded measured data output (CMS): - TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 16 Number of dynamic control inputs: 2 External device monitoring (EDM): + Incremental encoder inputs: + Number of application diagnostic outputs: 3 Electrical connection: System plug with or without connecting cable Number of static control inputs with EFI: 5 Type: Type 3 (IEC 61496) Measured data output: + Number of field sets: 8 Ambient operating temperature: -10 °C ... +50 °C Maximum warning field range: 49 m Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Distance measuring range: 49 m Protection class: II (EN 50178) Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Response time: 60 ms Type of field set: Dual field sets, Triple field sets PFHd: 8.0 1E-08 (EN ISO 13849) Performance level: PL d (EN ISO 13849) Number of reset-/restart inputs: 1 Hazardous area protection (horizontal): + Weight: 3.3 kg Configuration and diagnostics interface: RS-232 Safe SICK device communication via EFI/SDL: + Enclosure rating: IP 65 (EN 60529) Category: Category 3 (EN ISO 13849) Data interface: RS-422 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Number of EDM inputs: 1 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Maximum output current: 500 mA Static protective field switching: + Number of simultaneously monitored protective fields: ≤ 4 Integrated configuration memory: + Hazardous area protection (vertical): + Protective field range: 7 m Number of safe outputs: 2, Safety outputs (OSSD) Number of static control inputs: 4 Dimensions (W x H x D): 155 mm x 185 mm x 160 mm