Specification: Part Number 1023893 Number of EDM inputs: 1 PFHd: 8.0 1E-08 (EN ISO 13849) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Performance level: PL d (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Protection class: II (EN 50178) Maximum warning field range: 49 m Number of multiple samplings: Configurable 2 ... 16 Number of static control inputs with EFI: 5 Scan angle: 190 ° Maximum output current: 500 mA Weight: 3.3 kg Configuration and diagnostics interface: RS-232 Access protection (vertical): + Number of safe outputs: 2, Safety outputs (OSSD) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Number of reset-/restart inputs: 1 Static protective field switching: + Enclosure rating: IP 65 (EN 60529) Distance measuring range: 49 m Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Number of simultaneously monitored protective fields: ≤ 4 Expanded measured data output (CMS): - TM (mission time): 20 a (EN ISO 13849) Number of application diagnostic outputs: 3 Measured data output: + External device monitoring (EDM): + Data interface: RS-422 Integrated configuration memory: + Safe SICK device communication via EFI/SDL: + Response time: 60 ms Category: Category 3 (EN ISO 13849) Protective field range: 7 m Type: Type 3 (IEC 61496) Number of monitoring cases: 32 Hazardous area protection (horizontal): + Hazardous area protection (vertical): + Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Incremental encoder inputs: + Electrical connection: System plug with or without connecting cable Number of field sets: 32 Type of field set: Dual field sets, Triple field sets