S30A-6111DP

Specification: Part Number 1045653 Incremental encoder inputs: - Weight: 3.3 kg Response time: 60 ms Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Maximum warning field range: 49 m Hazardous area protection (horizontal): + Expanded measured data output (CMS): - Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer Type: Type 3 (IEC 61496) Category: Category 3 (EN ISO 13849) Hazardous area protection (vertical): + Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable PFHd: 8.0 1E-08 (EN ISO 13849) Access protection (vertical): + Safe SICK device communication via EFI/SDL: - Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Static protective field switching: + Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Number of simultaneously monitored protective fields: 2 Scan angle: 190 ° Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. Ambient operating temperature: -10 °C ... +50 °C Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Number of monitoring cases: 16 Conformance: Conformance Class B Protection class: III (VDE 0106, EN 60950) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Performance level: PL d (EN ISO 13849) Measured data output: + TM (mission time): 20 a (EN ISO 13849) Functions that are not supported: Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Integrated configuration memory: + Number of multiple samplings: Configurable 2 ... 16 Number of field sets: 8 Distance measuring range: 49 m Configuration and diagnostics interface: RS-232 Protective field range: 5.5 m Type of field set: Dual field sets Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Electrical connection: Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable External device monitoring (EDM): - Enclosure rating: IP 65 (EN 60529)
Part Number S30A-6111DP
Manufacture SICK
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com