Specification: Part Number 1045650 Hazardous area protection (horizontal): + Number of multiple samplings: Configurable 2 ... 16 Performance level: PL d (EN ISO 13849) Incremental encoder inputs: - Conformance: Conformance Class B Safe SICK device communication via EFI/SDL: - Maximum warning field range: 49 m Access protection (vertical): + Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 Weight: 3.3 kg Type: Type 3 (IEC 61496) Number of monitoring cases: 4 Measured data output: + Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. Functions that are not supported: Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Hazardous area protection (vertical): + Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Type of field set: Dual field sets PFHd: 8.0 1E-08 (EN ISO 13849) Protection class: III (VDE 0106, EN 60950) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Distance measuring range: 49 m Configuration and diagnostics interface: RS-232 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable External device monitoring (EDM): - Protective field range: 4 m Response time: 60 ms Static protective field switching: + Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Number of simultaneously monitored protective fields: 2 Integrated configuration memory: + Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer Category: Category 3 (EN ISO 13849) Scan angle: 190 ° Electrical connection: Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable TM (mission time): 20 a (EN ISO 13849) Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Enclosure rating: IP 65 (EN 60529) Ambient operating temperature: -10 °C ... +50 °C Number of field sets: 4 Expanded measured data output (CMS): -