Specification: Part Number 1052592 Switch properties: Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Incremental encoder inputs: - Topology support: SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Integrated configuration memory: + Enclosure rating: IP 65 (EN 60529) Number of monitoring cases: 16 Performance level: PL d (EN ISO 13849) Hazardous area protection (horizontal): + Diagnostics: Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Maintenance alerts for POF interfaces for signal quality Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 Protective field range: 4 m Expanded measured data output (CMS): - Type of field set: Dual field sets Number of multiple samplings: Configurable 2 ... 16 External device monitoring (EDM): - Conformance: Conformance Class B Device properties: GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. TM (mission time): 20 a (EN ISO 13849) PFHd: 8.0 1E-08 (EN ISO 13849) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Protection class: III (VDE 0106, EN 60950) Number of simultaneously monitored protective fields: 2 Hazardous area protection (vertical): + Access protection (vertical): + Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Electrical connection: Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-FX Distance measuring range: 49 m Maximum warning field range: 49 m Configuration and diagnostics interface: RS-232 Response time: 60 ms Static protective field switching: + Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Type: Type 3 (IEC 61496) Scan angle: 190 ° Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Measured data output: + Number of field sets: 8 Functions that are not supported: Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control Weight: 3.3 kg Category: Category 3 (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Safe SICK device communication via EFI/SDL: -