Specification: Part Number 1023547 Number of static control inputs: 2 Number of EDM inputs: 1 Configuration and diagnostics interface: RS-232 PFHd: 8.0 1E-08 (EN ISO 13849) Static protective field switching: + Number of field sets: 4 Maximum warning field range: 49 m Safe SICK device communication via EFI/SDL: + Protection class: II (EN 50178) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Data interface: RS-422 Number of multiple samplings: Configurable 2 ... 16 Measured data output: + Number of application diagnostic outputs: 3 Integrated configuration memory: + Expanded measured data output (CMS): - Performance level: PL d (EN ISO 13849) Number of simultaneously monitored protective fields: ≤ 4 Distance measuring range: 49 m TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 4 Type: Type 3 (IEC 61496) Protective field range: 5.5 m Number of static control inputs with EFI: 5 Response time: 60 ms Electrical connection: System plug with or without connecting cable Number of reset-/restart inputs: 1 Number of safe outputs: 2, Safety outputs (OSSD) Maximum output current: 500 mA Hazardous area protection (horizontal): + Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Hazardous area protection (vertical): + Enclosure rating: IP 65 (EN 60529) Incremental encoder inputs: - Ambient operating temperature: -10 °C ... +50 °C Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) External device monitoring (EDM): + Category: Category 3 (EN ISO 13849) Type of field set: Dual field sets, Triple field sets Weight: 3.3 kg Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Scan angle: 190 ° Access protection (vertical): +