Specification: Part Number 1028935 Maximum output current: 500 mA Number of field sets: 4 Number of simultaneously monitored protective fields: ≤ 4 External device monitoring (EDM): + Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Number of EDM inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Hazardous area protection (vertical): + Safe SICK device communication via EFI/SDL: + Protection class: II (EN 50178) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Enclosure rating: IP 65 (EN 60529) Distance measuring range: 49 m Protective field range: 4 m Hazardous area protection (horizontal): + Weight: 3.3 kg Ambient operating temperature: -10 °C ... +50 °C Maximum warning field range: 49 m Scan angle: 190 ° Type: Type 3 (IEC 61496) TM (mission time): 20 a (EN ISO 13849) Configuration and diagnostics interface: RS-232 Integrated configuration memory: + Electrical connection: System plug with or without connecting cable Number of static control inputs: 2 Measured data output: + Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Type of field set: Dual field sets, Triple field sets Category: Category 3 (EN ISO 13849) Performance level: PL d (EN ISO 13849) Static protective field switching: + Incremental encoder inputs: - Response time: 60 ms Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Number of application diagnostic outputs: 3 Access protection (vertical): + Number of monitoring cases: 4 PFHd: 8.0 1E-08 (EN ISO 13849) Number of safe outputs: 2, Safety outputs (OSSD) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Expanded measured data output (CMS): - Number of static control inputs with EFI: 5 Number of reset-/restart inputs: 1 Data interface: RS-422