Specification: Part Number 1050193 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Number of EDM inputs: 1 Safe SICK device communication via EFI/SDL: + Number of stand-by inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Access protection (vertical): + Data interface: RS-422 Enclosure rating: IP 65 (EN 60529) Response time: 80 ms Integrated configuration memory: + PFHd: 8.0 1E-08 (EN ISO 13849) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Ambient operating temperature: -10 °C ... +50 °C Dimensions (W x H x D): 102 mm x 152 mm x 106 mm Type of field set: Triple field sets Number of safe outputs: 2, Safety outputs (OSSD) Number of application diagnostic outputs: 3 Type: Type 3 (IEC 61496) Number of reset-/restart inputs: 1 Electrical connection: System plug with or without connecting cable Number of monitoring cases: 32 Hazardous area protection (horizontal): + Measured data output: + TM (mission time): 20 a (EN ISO 13849) Distance measuring range: 30 m Hazardous area protection (vertical): + Static protective field switching: + Performance level: PL d (EN ISO 13849) Number of static control inputs: 3 Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Number of field sets: 16 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Weight: 1.2 kg Protective field range: 2 m Number of static control inputs with EFI: 5 External device monitoring (EDM): + Maximum output current: 250 mA Expanded measured data output (CMS): + Category: Category 3 (EN ISO 13849) Maximum warning field range: 8 m Configuration and diagnostics interface: RS-232 Protection class: II (EN 50178) Scan angle: 270 ° Incremental encoder inputs: + Number of universal I/Os: 5 Number of dynamic control inputs: 2