Specification: Part Number 1056428 Maximum warning field range: 8 m Type of field set: Triple field sets Enclosure rating: IP 65 (EN 60529) Measured data output: + Hazardous area protection (vertical): + Number of universal I/Os: 5 Configuration and diagnostics interface: RS-232 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Protective field range: 3 m Number of application diagnostic o
Specification: Part Number 1056429 Number of dynamic control inputs: 2 Distance measuring range: 30 m Safe SICK device communication via EFI/SDL: + Type of field set: Triple field sets Number of universal I/Os: 5 Incremental encoder inputs: + Number of monitoring cases: 32 Number of field sets: 8 Electrical connection: System plug with or without connecting cable Performance level: PL d (EN ISO 13849
Specification: Part Number 1057641 PFHd: 8.0 1E-08 (EN ISO 13849) Distance measuring range: 30 m External device monitoring (EDM): + Protection class: III (EN 50178) Dimensions (W x H x D): 102 mm x 152 mm x 106 mm Hazardous area protection (vertical): + Number of monitoring cases: 32 Electrical connection: System plug with or without connecting cable Type: Type 3 (IEC 61496) Supply voltage: 16.8 V DC
Specification: Part Number 1041648 Protection class: II (EN 50178) Maximum output current: 500 mA Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Number of application diagnostic outputs: 2 Category: Category 3 (EN ISO 13849) Incremental encoder inputs: - Electrical connection: System plug Performance level: PL d (EN ISO 13849) PFHd: 8.0 1E-08 (EN ISO 13849) Hazardous area protection (hor
The S300 mini is the most compact Sick laser scanner available with dimensions of just h116 x w102 x d105mm. This compact size increases the number of applications that laser scanners can be used in. Series of safty laser scanner with very compact design. It has 270° scan angle and 2m protective field range. The main characteristics of S32B-2011BA: Part Number: 1050932; Electrical connection: Cable, 250 mm, with male connector M12, 8
Specification: Part Number 1051884 Number of outputs: Depends on the configuration of the connected EFI device Number of field sets: 16 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Measured data output: - Weight: 0.8 kg, without connecting cables Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Incremental encoder inputs: + Distance measuring range: 30 m Category: Category 3 (EN ISO 1384
Specification: Part Number 1056430 Static protective field switching: - Category: Category 3 (EN ISO 13849) Protective field range: 3 m Distance measuring range: 30 m Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Response time: 80 ms Enclosure rating: IP 65 (EN 60529) Hazardous area protection (vertical): + Hazardous area protection (horizontal): + Number of safe outputs: 2, Safety ou
Specification: Part Number 1056431 Number of static control inputs with EFI: 5 Protective field range: 3 m Electrical connection: Cable, 250 mm, with male connector M12, 7-pin Safe SICK device communication via EFI/SDL: + Enclosure rating: IP 65 (EN 60529) Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Ambient operating temperature: -10 °C ... +50 °C Type of field set: Triple field sets Scan angle: 270 °
Specification: Part Number 1028936 Number of reset-/restart inputs: 1 Enclosure rating: IP 65 (EN 60529) Number of safe outputs: 2, Safety outputs (OSSD) Maximum warning field range: 49 m Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Electrical connection: System plug with or without connecting cable Maximum output current: 500 mA Number of dynamic control inputs: 2 Static protective field sw
Specification: Part Number 2049566 Hazardous area protection (horizontal): + TM (mission time): 20 a (EN ISO 13849) Performance level: PL d (EN ISO 13849) Category: Category 3 (EN ISO 13849) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Hazardous area protection (vertical): + Response time: 60 ms PFHd: 8.0 1E-08 (EN ISO 13849) Protection class: III (EN 50178) Integrated configuration m
Specification: Part Number 1052108 Number of static control inputs with EFI: 5 Access protection (vertical): + Measured data output: + Number of EDM inputs: 1 PFHd: 8.0 1E-08 (EN ISO 13849) Category: Category 3 (EN ISO 13849) Number of simultaneously monitored protective fields: ≤ 4 Number of multiple samplings: Configurable 2 ... 16 Hazardous area protection (vertical): + TM (mission time): 20 a
Specification: Part Number 2049567 Category: Category 3 (EN ISO 13849) TM (mission time): 20 a (EN ISO 13849) Integrated configuration memory: + Enclosure rating: IP 65 (EN 60529) External device monitoring (EDM): - PFHd: 8.0 1E-08 (EN ISO 13849) Scan angle: 190 ° Hazardous area protection (vertical): + Protective field range: 5.5 m Number of simultaneously monitored protective fields: 2 Type:
Specification: Part Number 2049568 External device monitoring (EDM): - Category: Category 3 (EN ISO 13849) Protective field range: 7 m Integrated configuration memory: + Ambient operating temperature: -10 °C ... +50 °C Access protection (vertical): + Number of simultaneously monitored protective fields: 2 PFHd: 8.0 1E-08 (EN ISO 13849) Scan angle: 190 ° Protection class: III (EN 50178)
Specification: Part Number 2057645 Performance level: PL d (EN ISO 13849) Data interface: RS-422 Category: Category 3 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) TM (mission time): 20 a (EN ISO 13849) Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Electrical connection: System plug with or without connecting cable Number of simultaneously monitored protective fields: ≤ 4 Configuration and diagnosti
Specification: Part Number 1058000 Number of EDM inputs: 1 Safe SICK device communication via EFI/SDL: - Integrated configuration memory: - Type: Type 3 (IEC 61496) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Maximum warning field range: 8 m External device monitoring (EDM): + Hazardous area protection (vertical): + Configuration and diagnostics interface: RS-232 Static protective fi