S30A-7111

Specification: Part Number 2049568 External device monitoring (EDM): - Category: Category 3 (EN ISO 13849) Protective field range: 7 m Integrated configuration memory: + Ambient operating temperature: -10 °C ... +50 °C Access protection (vertical): + Number of simultaneously monitored protective fields: 2 PFHd: 8.0 1E-08 (EN ISO 13849) Scan angle: 190 ° Protection class: III (EN 50178) Type: Type 3 (IEC 61496) Enclosure rating: IP 65 (EN 60529) Performance level: PL d (EN ISO 13849) Response time: 60 ms Hazardous area protection (horizontal): + Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Hazardous area protection (vertical): + Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) TM (mission time): 20 a (EN ISO 13849)