Specification: Part Number 1058000 Number of EDM inputs: 1 Safe SICK device communication via EFI/SDL: - Integrated configuration memory: - Type: Type 3 (IEC 61496) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Maximum warning field range: 8 m External device monitoring (EDM): + Hazardous area protection (vertical): + Configuration and diagnostics interface: RS-232 Static protective field switching: - Category: Category 3 (EN ISO 13849) Access protection (vertical): + Expanded measured data output (CMS): - Response time: 80 ms Protective field range: 1 m Enclosure rating: IP 65 (EN 60529) Incremental encoder inputs: - Scan angle: 270 ° Dimensions (W x H x D): 102 mm x 116 mm x 105 mm Distance measuring range: 30 m Measured data output: - Number of universal I/Os: 2 PFHd: 8.0 1E-08 (EN ISO 13849) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Hazardous area protection (horizontal): + Type of field set: Triple field sets Performance level: PL d (EN ISO 13849) Weight: 0.8 kg, without connecting cables Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Protection class: III (EN 50178) TM (mission time): 20 a (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Number of warning field outputs: 2 Number of safe outputs: 2, Safety outputs (OSSD) Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Number of stand-by inputs: 1 Electrical connection: Cable, 250 mm, with male connector M12, 8-pin Number of reset-/restart inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Number of field sets: 1