S31A-7011CA

Specification: Part Number 1041648 Protection class: II (EN 50178) Maximum output current: 500 mA Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Number of application diagnostic outputs: 2 Category: Category 3 (EN ISO 13849) Incremental encoder inputs: - Electrical connection: System plug Performance level: PL d (EN ISO 13849) PFHd: 8.0 1E-08 (EN ISO 13849) Hazardous area protection (horizontal): + Number of monitoring cases: 4 Number of field sets: 4 Ambient operating temperature: -30 °C ... +50 °C Measured data output: - Response time: 60 ms External device monitoring (EDM): - Supply voltage heating: 16.8 V DC, 24 V DC, 28.8 V DC Number of static control inputs with EFI: 5 Weight: 9 kg TM (mission time): 20 a (EN ISO 13849) Protective field range: 7 m Dimensions (W x H x D): 351 mm x 265 mm x 221 mm Configuration and diagnostics interface: RS-232 Safe SICK device communication via EFI/SDL: + Supply voltage scanner: 17.5 V DC, 24 V DC, 28.8 V DC Number of multiple samplings: Configurable 2 ... 16 Enclosure rating: IP 65 (EN 60529), IP 67 (EN 60529) Distance measuring range: 49 m Hazardous area protection (vertical): + Integrated configuration memory: - Access protection (vertical): + Static protective field switching: + Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Number of safe outputs: 2, Safety outputs (OSSD) Type: Type 3 (IEC 61496) Number of static control inputs: 2 Maximum warning field range: 49 m Scan angle: 180 ° Number of simultaneously monitored protective fields: ≤ 4 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Expanded measured data output (CMS): -
Part Number S31A-7011CA
Manufacture SICK
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com