Specification: Part Number 1051884 Number of outputs: Depends on the configuration of the connected EFI device Number of field sets: 16 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Measured data output: - Weight: 0.8 kg, without connecting cables Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Incremental encoder inputs: + Distance measuring range: 30 m Category: Category 3 (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Static protective field switching: + Performance level: PL d (EN ISO 13849) Number of stand-by inputs: 1 Dimensions (W x H x D): 102 mm x 116 mm x 105 mm Safe SICK device communication via EFI/SDL: + Protective field range: 2 m Configuration and diagnostics interface: RS-232 Number of static control inputs with EFI: 5 TM (mission time): 20 a (EN ISO 13849) External device monitoring (EDM): - Enclosure rating: IP 65 (EN 60529) Type: Type 3 (IEC 61496) Hazardous area protection (vertical): + Scan angle: 270 ° Protection class: III (EN 50178) Maximum warning field range: 8 m Type of field set: Triple field sets Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Expanded measured data output (CMS): - Number of multiple samplings: Configurable 2 ... 16 PFHd: 8.0 1E-08 (EN ISO 13849) Access protection (vertical): + Hazardous area protection (horizontal): + Electrical connection: Cable, 250 mm, with male connector M12, 7-pin Integrated configuration memory: - Response time: 80 ms