Specification: Part Number 1056431 Number of static control inputs with EFI: 5 Protective field range: 3 m Electrical connection: Cable, 250 mm, with male connector M12, 7-pin Safe SICK device communication via EFI/SDL: + Enclosure rating: IP 65 (EN 60529) Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Ambient operating temperature: -10 °C ... +50 °C Type of field set: Triple field sets Scan angle: 270 ° Number of outputs: Depends on the configuration of the connected EFI device Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Maximum warning field range: 8 m Static protective field switching: + Incremental encoder inputs: + Expanded measured data output (CMS): - Number of stand-by inputs: 1 Type: Type 3 (IEC 61496) Integrated configuration memory: - Hazardous area protection (vertical): + Number of field sets: 16 Configuration and diagnostics interface: RS-232 Response time: 80 ms Protection class: III (EN 50178) Weight: 0.8 kg, without connecting cables PFHd: 8.0 1E-08 (EN ISO 13849) Measured data output: - Hazardous area protection (horizontal): + Number of multiple samplings: Configurable 2 ... 16 Access protection (vertical): + Performance level: PL d (EN ISO 13849) Category: Category 3 (EN ISO 13849) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) TM (mission time): 20 a (EN ISO 13849) Dimensions (W x H x D): 102 mm x 116 mm x 105 mm External device monitoring (EDM): - Distance measuring range: 30 m