Specification: Part Number 1062282 Process pressure: -1 bar ... 10 bar Output current: < 100 mA Signal voltage LOW: ≤ 2 V Power consumption: ≤ 100 mA at 24 V DC without output load Wetted parts: 1.4404, PTFE Process temperature: -20 °C ... +100 °C MTTF: 194.3 a (EN ISO 13849-1) Max.probe load: 6 Nm Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable,
Specification: Part Number 1066791 Protection class: III Medium: Fluids Wetted parts: 1.4404, PTFE Lower signal level: 3.8 mA ... 4 mA Process temperature: -20 °C ... +100 °C Power consumption: ≤ 100 mA at 24 V DC without output load MTTF: 194.3 a (EN ISO 13849-1) Supply voltage: 12 V DC ... 30 V DC Output current: < 100 mA Process pressure: -1 bar ... 10 bar EMC: EN 61326-1:2006, 2004/108/E
Specification: Part Number 1071120 Capacitive load: 100 nF Ambient temperature coaxial cable: -20 °C ... +60 °C Output current: < 100 mA UL approval: + Upper signal level: 20 mA ... 20.5 mA Housing material: 303 Signal voltage LOW: ≤ 2 V Ambient storage temperature: -40 °C ... +80 °C Interference resistance: EN 61000-6-2:2005 Hysteresis: Min. 2 mm, free adjustable Measurement: Switch, Conti
Specification: Part Number 1071129 Process connection: G ¾ A Housing design: With closed cover Interference resistance: EN 61000-6-2:2005 Process temperature: -20 °C ... +180 °C IO-Link: + Process pressure: -1 bar ... 16 bar Ambient storage temperature: -40 °C ... +80 °C Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V
Specification: Part Number 1071131 Interference resistance: EN 61000-6-2:2005 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Housing design: With closed cover Upper signal level: 20 mA ... 20.5 mA Initialization time: ≤ 2 s Hysteresis: Min. 2 mm, free adjustable Process temperature: -20 °C ... +180 °C Ambient storage temperature: -40 °C ... +80 °C Accuracy of sensor element: ± 5 mm RoHS certificate
Specification: Part Number 1056302 GOST approval: + Capacitive load: 100 nF UL approval: + Power consumption: ≤ 75 mA at 24 V DC without output load Ambient temperature operation: -20 °C ... +60 °C Signal voltage HIGH: Vs - 2 V Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Medium: Fluids Inductive load: < 1 H
Specification: Part Number 1071135 Temperature drift: < 0.1 mm/K Supply voltage: 12 V DC ... 30 V DC Probe length: 2,000 mm Interference emission: EN 61000-6-4:2007 Process temperature: -20 °C ... +180 °C EMC: EN 61326-1:2006, 2004/108/EG Max.probe load: 6 Nm Signal voltage HIGH: Vs - 2 V Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500
Specification: Part Number 1071138 UL approval: + Hysteresis: Min. 2 mm, free adjustable Process temperature: -20 °C ... +180 °C Upper signal level: 20 mA ... 20.5 mA Inductive load: < 1 H Inactive area at process connector: 25 mm Single- and continuous shock: EN 60068-2-27 Temperature drift: < 0.1 mm/K Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Ambient temperature coaxial cable: -20 °C ... +60
Specification: Part Number 1071144 Output current: < 100 mA Length coaxial cable: 1 m, FEP Power consumption: ≤ 75 mA at 24 V DC without output load RoHS certificate: + Inactive area at probe end: 10 mm Supply voltage: 12 V DC ... 30 V DC Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Response time: < 400 ms Hyst
Specification: Part Number 1071146 Initialization time: ≤ 2 s Lower signal level: 3.8 mA ... 4 mA Process pressure: -1 bar ... 16 bar Repeatability: ≤ 2 mm Hysteresis: Min. 2 mm, free adjustable Probe length: 2,000 mm Measurement: Switch, Continuous Accuracy of sensor element: ± 5 mm Power consumption: ≤ 75 mA at 24 V DC without output load Upper signal level: 20 mA ... 20.5 mA Enclosure r
Specification: Part Number 1065358 Resolution: < 2 mm Output current: < 100 mA Interference emission: EN 61000-6-4:2007 Response time: < 400 ms Housing material: 303 GOST approval: + Single- and continuous shock: EN 60068-2-27 Capacitive load: 100 nF Signal voltage LOW: ≤ 2 V Housing design: With PMMA viewing window Ambient storage temperature: -40 °C ... +80 °C 3-A: - Repeatability
Specification: Part Number 1065359 Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Housing design: With PMMA viewing window UL approval: + RoHS certificate: + Resolution: < 2 mm Hysteresis: Min. 2 mm, free adjustable Inductive load: < 1 H Signal voltage HIGH: Vs - 2 V Interference emission: EN 61000-6-4:2007 Capacit
Specification: Part Number 1065360 Resolution: < 2 mm Repeatability: ≤ 2 mm RoHS certificate: + EMC: EN 61326-1:2006, 2004/108/EG Accuracy of sensor element: ± 5 mm Inactive area at probe end: 10 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V EHEDG approval: + Hysteresis: Min. 2 mm, free adjustable Dielectri
Specification: Part Number 1065362 Process pressure: -1 bar ... 16 bar Power consumption: ≤ 75 mA at 24 V DC without output load Signal voltage HIGH: Vs - 2 V Interference resistance: EN 61000-6-2:2005 Inactive area at probe end: 10 mm Output current: < 100 mA Housing design: With PMMA viewing window Hysteresis: Min. 2 mm, free adjustable Supply voltage: 12 V DC ... 30 V DC Housing material: 303
Specification: Part Number 1065363 Housing design: With PMMA viewing window Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Max.probe load: 6 Nm Hysteresis: Min. 2 mm, free adjustable Output current: < 100 mA RoHS certificate: + Signal voltage HIGH: Vs - 2 V Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Signal voltage LOW: ≤ 2 V Inactive area at process connector: 25 mm
Specification: Part Number 1064856 EHEDG approval: + EMC: EN 61326-1:2006, 2004/108/EG Max.probe load: 6 Nm Housing material: 303 Measurement: Switch, Continuous UL approval: + Accuracy of sensor element: ± 5 mm GOST approval: + Medium: Fluids Repeatability: ≤ 2 mm Inactive area at process connector: 25 mm MTTF: 194.3 a (EN ISO 13849-1) IO-Link: + Housing design: With PMMA viewing
Specification: Part Number 1065346 Housing material: 303 Inductive load: < 1 H Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Process pressure: -1 bar ... 16 bar EHEDG approval: + GOST approval: + MTTF: 194.3 a (EN ISO 13849-1) Ambient storage temperature: -40 °C ... +80 °C Medium: Fluids Power consumption: ≤ 75 mA at 24 V DC without output load RoHS certificate: + Process connection:
Specification: Part Number LFP3000-E4CMB EMC: EN 61326-1:2006, 2004/108/EG Housing material: Plastic PBT Hysteresis: Min. 2 mm, free adjustable Signal voltage HIGH: Vs - 2 V Upper signal level: 20 mA ... 20.5 mA Maximum level change: 500 mm/s Supply voltage: 12 V DC ... 30 V DC Ambient temperature operation: -20 °C ... +60 °C Connection type: Round connector M12 x 1, 5-pin CULus certificate: + Ou
Specification: Part Number 1072031 Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Accuracy of sensor element: ± 5 mm Temperature drift: < 0.1 mm/K Signal voltage LOW: ≤ 2 V RoHS certificate: + Inactive area at probe end: 10 mm GOST approval: + Interference emission: EN 61000-6-4:2007 Single- and continuous shock:
Specification: Part Number 1072032 Inductive load: < 1 H Measurement: Switch, Continuous Supply voltage: 12 V DC ... 30 V DC Repeatability: ≤ 2 mm Output current: < 100 mA Power consumption: ≤ 75 mA at 24 V DC without output load Process connection: ¾" NPT Ambient storage temperature: -40 °C ... +80 °C Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 EHEDG approval: + Protection class
Specification: Part Number 1065348 Temperature drift: < 0.1 mm/K Response time: < 400 ms IO-Link: + Lower signal level: 3.8 mA ... 4 mA Ambient storage temperature: -40 °C ... +80 °C Conductivity: No limitation Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe 3-A: - Accuracy of sensor element: ± 5 mm Capacitive load: 100 nF Interference emission: EN 61000-6-4:2007
Specification: Part Number 1065349 Inductive load: < 1 H 3-A: - Probe length: 3,200 mm Inactive area at probe end: 10 mm Upper signal level: 20 mA ... 20.5 mA EMC: EN 61326-1:2006, 2004/108/EG Accuracy of sensor element: ± 5 mm Protection class: III Lower signal level: 3.8 mA ... 4 mA RoHS certificate: + Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Repeatability: ≤ 2 mm Connecti
Specification: Part Number 1065350 RoHS certificate: + Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe GOST approval: + Ambient storage temperature: -40 °C ... +80 °C Protection class: III Hysteresis: Min. 2 mm, free adjustable EMC: EN 61326-1:2006, 2004/108/EG Temperature drift: < 0.1 mm/K Initialization time: ≤ 2 s EHEDG approval: + Response time: < 400 ms UL
Specification: Part Number 1065351 Inactive area at process connector: 25 mm Ambient temperature operation: -20 °C ... +60 °C Max.probe load: 6 Nm Interference resistance: EN 61000-6-2:2005 Signal voltage HIGH: Vs - 2 V Inductive load: < 1 H Connection type: Round connector M12 x 1, 5-pin GOST approval: + Supply voltage: 12 V DC ... 30 V DC Resolution: < 2 mm Repeatability: ≤ 2 mm IO-Li
Specification: Part Number 1065353 Housing design: With PMMA viewing window Response time: < 400 ms Signal voltage LOW: ≤ 2 V Interference emission: EN 61000-6-4:2007 Output current: < 100 mA Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Repeatability: ≤ 2 mm Measurement: Switch, Continuous Hysteresis: Min. 2 mm, free adjustable Max.probe load: 6 Nm Ambient temperature operation: -20
Specification: Part Number 1065354 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe EMC: EN 61326-1:2006, 2004/108/EG Lower signal level: 3.8 mA ... 4 mA Inactive area at probe end: 10 mm Repeatability: ≤ 2 mm Housing design: With PMMA viewing window EHEDG approval: + Process connection: G ¾ A Inductive load: < 1 H Signal vol
Specification: Part Number 1065355 Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Resolution: < 2 mm Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Ambient temperature operation: -20 °C ... +60 °C Accuracy of sensor element: ± 5 mm EHEDG approval: + Interference resistance: EN 61000-6-2:2005 IO-Link: + MTTF: 194.3 a (EN ISO 13849-1) Probe length: 3,800 mm Output c
Specification: Part Number 1065356 GOST approval: + Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe 3-A: - Connection type: Round connector M12 x 1, 5-pin Inactive area at probe end: 10 mm Hysteresis: Min. 2 mm, free adjustable Ambient storage temperature: -40 °C ... +80 °C Accuracy of sensor element: ± 5 mm Temperature drift: < 0.1 mm/K Output load: 0 V ... 10 V > 750 Oh
Specification: Part Number LFP4000-E4BMB Signal voltage LOW: ≤ 2 V Process connection: G ¾ A Response time: < 400 ms RoHS certificate: + Maximum level change: 500 mm/s Inductive load: < 1 H Capacitive load: 100 nF IO-Link: + GOST approval: + Inactive area at process connector: 25 mm Protection class: III CULus certificate: + Power consumption: ≤ 100 mA at 24 V DC without output lo
Specification: Part Number 1070139 Supply voltage: 12 V DC ... 30 V DC Conductivity: No limitation Power consumption: ≤ 100 mA at 24 V DC without output load Response time: < 400 ms Signal voltage LOW: ≤ 2 V Upper signal level: 20 mA ... 20.5 mA Probe type: Rope probe Ambient storage temperature: -40 °C ... +80 °C Protection class: III Wetted parts: 1.4404, PTFE Resolution: < 2 mm Enc