Specification: Part Number 1065360 Resolution: < 2 mm Repeatability: ≤ 2 mm RoHS certificate: + EMC: EN 61326-1:2006, 2004/108/EG Accuracy of sensor element: ± 5 mm Inactive area at probe end: 10 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V EHEDG approval: + Hysteresis: Min. 2 mm, free adjustable Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Process temperature: -20 °C ... +150 °C Protection class: III Ambient storage temperature: -40 °C ... +80 °C GOST approval: + Interference emission: EN 61000-6-4:2007 Process connection: G ¾ A Inactive area at process connector: 25 mm Single- and continuous shock: EN 60068-2-27 IO-Link: + UL approval: + Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Signal voltage LOW: ≤ 2 V Output current: < 100 mA Response time: < 400 ms Inductive load: < 1 H Housing material: 303 Signal voltage HIGH: Vs - 2 V Medium: Fluids Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Capacitive load: 100 nF Max.probe load: 6 Nm MTTF: 194.3 a (EN ISO 13849-1) Probe length: 2,400 mm Housing design: With PMMA viewing window Conductivity: No limitation Temperature drift: < 0.1 mm/K Power consumption: ≤ 75 mA at 24 V DC without output load Ambient temperature operation: -20 °C ... +60 °C 3-A: - Process pressure: -1 bar ... 16 bar Upper signal level: 20 mA ... 20.5 mA Interference resistance: EN 61000-6-2:2005 Supply voltage: 12 V DC ... 30 V DC Lower signal level: 3.8 mA ... 4 mA Connection type: Round connector M12 x 1, 5-pin Measurement: Switch, Continuous Initialization time: ≤ 2 s