SICK - Fluid sensors

Image
Part Number
Description
Specification: Part Number 6049016 Upper signal level: 20 mA ... 20.5 mA Minimim flow: 0.3 l/min Housing material: PSU Signal voltage LOW: ≤ 2 V Resolution: 0.003 l/min Maximum flow: 21 l/min Impuls/frequency output: 0 kHz ... 10 kHz Process temperature: 0 °C ... +80 °C Inductive load: 1 H Power consumption: ≤ 180 mA Accuracy of sensor element: 1 % (of reading +/- 3 mm/s (with calibratio
Specification: Part Number 6049017 Capacitive load: 100 nF Weight: 350 g Output current: < 100 mA Impuls/frequency output: 0 kHz ... 10 kHz Output signal: Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature 1 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (depending on type) Maximum flow: 36 l/min Accuracy
Specification: Part Number 6049018 Process temperature: 0 °C ... +80 °C Output load: < 500 Ohm Process connection: G 1 Output signal: Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature 1 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (depending on type) Upper signal level: 20 mA ... 20.5 mA Repeatability: &le
Specification: Part Number 6049019 Puls width: &le; 1 s Minimim flow: 5 l/min Ripple: &le; 5 Vpp Capacitive load: 100 nF Connection type: Round connector M12 x 1, 5-pin Housing material: PSU Signal voltage LOW: &le; 2 V Output signal: Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature 1 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring, d
Specification: Part Number 6052239 Maximum flow: 240 l/min Accuracy of sensor element: 1 % (of reading +/- 3 mm/s (with calibration report)) Minimim flow: 5 l/min Inlet zone: 60 cm Upper signal level: 20 mA ... 20.5 mA Ripple: &le; 5 Vpp Housing material: PSU Conductivity: No limitation Medium: Fluids Initialization time: &le; 5 s Wetted parts: PSU Capacitive load: 100 nF Ambient storage
Specification: Part Number 6049101 Impuls/frequency output: 0 kHz ... 10 kHz Repeatability: &le; 0.5 % Weight: 340 g Inductive load: 1 H Lower signal level: 3.8 mA ... 4 mA Output current: < 100 mA Signal voltage LOW: &le; 2 V Upper signal level: 20 mA ... 20.5 mA Supply voltage: 18 V DC ... 30 V DC Medium: Fluids Output load: < 500 Ohm Maximum flow: 21 l/min Wetted parts: PSU Proc
Specification: Part Number 6047868 Resolution: 0.003 l/min Signal voltage LOW: &le; 2 V Inlet zone: 20 cm Lower signal level: 3.8 mA ... 4 mA Initialization time: &le; 5 s Maximum flow: 21 l/min Ambient temperature operation: 0 °C ... +60 °C Ripple: &le; 5 Vpp Upper signal level: 20 mA ... 20.5 mA Output load: < 500 Ohm Process pressure: Max. 16 bar Process connection: ½'' NPT Ambient
Specification: Part Number 6043743 Supply voltage: 18 V DC ... 30 V DC Ripple: &le; 5 Vpp Accuracy of sensor element: 2 % (of final value) Puls width: &le; 1 s Initialization time: &le; 5 s Power consumption: &le; 180 mA Signal voltage LOW: &le; 2 V Medium: Fluids Process temperature: 0 °C ... +80 °C Process connection: G ½ Connection type: Round connector M12 x 1, 8-pin Process pressure:
Specification: Part Number 6045162 Repeatability: &le; 0.5 % Inlet zone: 30 cm Inductive load: 1 H Ambient storage temperature: -20 °C ... +70 °C Minimim flow: 0.9 l/min Process temperature: 0 °C ... +80 °C Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Connection type: Round connector M12 x 1, 5-pin Enclosure rating: IP 67 Maximum flow: 36 l/min Po
Specification: Part Number 6041249 Accuracy of sensor element: 2 % (of final value) Inductive load: 1 H Lower signal level: 3.8 mA ... 4 mA Process connection: G ¾ Weight: 350 g Ripple: &le; 5 Vpp Signal voltage HIGH: Vs - 2 V Protection class: III Supply voltage: 18 V DC ... 30 V DC Ambient temperature operation: 0 °C ... +60 °C Initialization time: &le; 5 s Process pressure: Max. 16 bar
Specification: Part Number 6043744 Process pressure: Max. 16 bar Lower signal level: 3.8 mA ... 4 mA Outlet zone: 5 cm Signal voltage LOW: &le; 2 V Enclosure rating: IP 67 Signal voltage HIGH: Vs - 2 V Wetted parts: PSU Protection class: III Capacitive load: 100 nF Medium: Fluids Initialization time: &le; 5 s Output load: < 500 Ohm Nominal width measuring tube: NW 15 Inlet zone: 30 cm
Specification: Part Number 6049061 Connection type: Round connector M12 x 1, 5-pin Supply voltage: 18 V DC ... 30 V DC Ripple: &le; 5 Vpp Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Puls width: &le; 1 s Wetted parts: PSU Outlet zone: 10 cm Nominal width measuring tube: NW 20 Medium: Fluids Maximum flow: 60 l/min Accuracy of sensor element: 2 % (of
Specification: Part Number 6041738 Ripple: &le; 5 Vpp Puls width: &le; 1 s Housing material: PSU Medium: Fluids Accuracy of sensor element: 2 % (of final value) Output current: < 100 mA Process pressure: Max. 10 bar Signal voltage HIGH: Vs - 2 V Minimim flow: 3.5 l/min Capacitive load: 100 nF Supply voltage: 18 V DC ... 30 V DC Initialization time: &le; 5 s Process temperature: 0 °C .
Specification: Part Number 6043745 Weight: 420 g Impuls/frequency output: 0 kHz ... 10 kHz Output load: < 500 Ohm Upper signal level: 20 mA ... 20.5 mA Supply voltage: 18 V DC ... 30 V DC Lower signal level: 3.8 mA ... 4 mA Nominal width measuring tube: NW 20 Process temperature: 0 °C ... +80 °C Protection class: III Resolution: 0.012 l/min Puls width: &le; 1 s Inductive load: 1 H Capac
Specification: Part Number 6044523 Minimim flow: 5 l/min Nominal width measuring tube: NW 25 Accuracy of sensor element: 2 % (of final value) Output load: < 500 Ohm Medium: Fluids Initialization time: &le; 5 s Puls width: &le; 1 s Process temperature: 0 °C ... +80 °C Enclosure rating: IP 67 Wetted parts: PSU Ambient storage temperature: -20 °C ... +70 °C Conductivity: No limitation Sig
Specification: Part Number 6041739 Ambient temperature operation: 0 °C ... +60 °C Maximum flow: 240 l/min Accuracy of sensor element: 2 % (of final value) Capacitive load: 100 nF Nominal width measuring tube: NW 25 Process connection: G 1 ¼ Inductive load: 1 H Ripple: &le; 5 Vpp Initialization time: &le; 5 s Wetted parts: PSU Resolution: 0.03 l/min Process temperature: 0 °C ... +80 °C
Specification: Part Number 6043746 Maximum flow: 240 l/min Impuls/frequency output: 0 kHz ... 10 kHz Upper signal level: 20 mA ... 20.5 mA Process temperature: 0 °C ... +80 °C Nominal width measuring tube: NW 25 Lower signal level: 3.8 mA ... 4 mA Medium: Fluids Wetted parts: PSU Process pressure: Max. 10 bar Enclosure rating: IP 67 Signal voltage LOW: &le; 2 V Inlet zone: 60 cm Inductiv
Specification: Part Number 6044996 Upper signal level: 20 mA ... 20.5 mA Inlet zone: 60 cm Process pressure: Max. 10 bar Process connection: 1 ¼" NPT Impuls/frequency output: 0 kHz ... 10 kHz Power consumption: &le; 180 mA Process temperature: 0 °C ... +80 °C Housing material: PSU Ripple: &le; 5 Vpp Weight: 460 g Wetted parts: PSU Medium: Fluids Initialization time: &le; 5 s Minimi
Specification: Part Number 6049566 Outlet zone: 10 cm Nominal width measuring tube: NW 25 Resolution: 0.03 l/min Ambient temperature operation: 0 °C ... +60 °C Puls width: &le; 1 s Inductive load: 1 H Output load: < 500 Ohm Process connection: 1 ¼" NPT Lower signal level: 3.8 mA ... 4 mA Process pressure: Max. 10 bar Upper signal level: 20 mA ... 20.5 mA Signal voltage LOW: &le; 2 V Init
Specification: Part Number 6038007 Process pressure: -1 bar ... 25 bar Particle size: < 10 mm Ambient storage temperature: -40 °C ... 80 °C Capacitive load: 100 nF Hysteresis: 10 mm ATEX certification: - Inductive load: 1 H VDE protection class 1: + Measurement: Switch Accuracy: ± 10 mm Sensor material: Stainless steel 1.4404 Enclosure rating: IP 66 Medium: Bulk solids Output current
Specification: Part Number 6038009 Ambient storage temperature: -40 °C ... 80 °C Hysteresis: 10 mm ATEX certification: - Output current: < 400 mA Housing material: Aluminum Particle size: < 10 mm Connection type: ½" NPT Enclosure rating: IP 66 Fill material density: 0.008 g/cm VDE protection class 1: + Ambient temperature operation: -40 °C ... 80 °C Process connection: G 1½ A PN 25 / 31
Specification: Part Number 6038006 Particle size: < 10 mm ATEX certification: - Housing material: Plastic Hysteresis: 10 mm Fill material density: 0.008 g/cm Output current: < 400 mA Initialization time: 3 s Process connection: G 1½ A PN 25 / 316L Ambient temperature operation: -40 °C ... 80 °C Process pressure: -1 bar ... 25 bar Enclosure rating: IP 66 VDE protection class 1: + Probe l
Specification: Part Number 6037753 VDE protection class 1: + Power consumption: 5 mA ... 30 mA Hysteresis: 10 mm Accuracy: ± 10 mm Switching output: Double relay (DPDT): 20 V DC ... 72 V DC / 20 ... 253 V AC Process temperature: -50 °C ... 150 °C Particle size: < 10 mm Measurement: Switch Connection type: M20x1,5 Enclosure rating: IP 66 ATEX certification: - Process pressure: -1 bar ... 25
Specification: Part Number 6038011 Accuracy: ± 10 mm Switching output: Double relay (DPDT): 20 V DC ... 72 V DC / 20 ... 253 V AC Initialization time: 2 s Housing material: Plastic Process connection: G 1½ A PN 25 / 316L Inductive load: 750 VA 54 W Response time: 500 ms Hysteresis: 10 mm Fill material density: 0.008 g/cm Probe length: 220 mm Particle size: < 10 mm Medium: Bulk solids Proc
Specification: Part Number 6038018 Initialization time: 2 s Enclosure rating: IP 66 Probe length: 220 mm Process temperature: -50 °C ... 150 °C Switching output: Transistor output PNP/ NPN: 10 V DC ... 55 V DC Measurement: Switch ATEX certification: - Housing material: Stainless steel (electropolished) 316L Process pressure: -1 bar ... 25 bar Hysteresis: 10 mm Fill material density: 0.008 g/cm
Specification: Part Number 6038017 Connection type: M20x1,5 ATEX certification: - Probe length: 220 mm Signal voltage LOW: < 1 V Initialization time: 2 s Output current: < 300 mA Accuracy: ± 10 mm Measurement: Switch Response time: 500 ms Ripple:
Specification: Part Number 6038020 Output current: < 300 mA VDE protection class 2: + Measurement: Switch Connection type: ½" NPT Probe length: 220 mm Ripple:
Specification: Part Number 6038016 Repeatability: ± 5 mm Power consumption: < 10 mA Ambient storage temperature: -40 °C ... 80 °C Measurement: Switch Process pressure: -1 bar ... 25 bar Signal voltage LOW: < 1 V Switching output: Transistor output PNP/ NPN: 10 V DC ... 55 V DC VDE protection class 2: + Hysteresis: 10 mm Housing material: Plastic Accuracy: ± 10 mm Inductive load: 1 H
Specification: Part Number 6039278 Medium: Bulk solids ATEX certification: - Inductive load: 1 H Process connection: G 1½ A PN 25 / 316L Enclosure rating: IP 66 Sensor material: Stainless steel 1.4404 Measurement: Switch Ambient storage temperature: -40 °C ... 80 °C Initialization time: 2 s Particle size: < 10 mm Ambient operating temperature: -40 °C ... 80 °C Connection type: M20x1,5
Specification: Part Number 6041250 Housing material: Aluminum Process pressure: -1 bar ... 25 bar Power consumption: 5 mA ... 30 mA Fill material density: 0.008 g/cm Inductive load: 750 VA 54 W Probe length: 220 mm Capacitive load: 750 VA 54 W VDE protection class 1: + Process connection: Flange DN 100 PN 6 Form C, DIN2501/ 316L Connection type: M20x1,5 Particle size: < 10 mm ATEX certification
Menu
Mail Us
enquiry@onstocktrading.com