Specification: Part Number 6049566 Outlet zone: 10 cm Nominal width measuring tube: NW 25 Resolution: 0.03 l/min Ambient temperature operation: 0 °C ... +60 °C Puls width: ≤ 1 s Inductive load: 1 H Output load: < 500 Ohm Process connection: 1 ¼" NPT Lower signal level: 3.8 mA ... 4 mA Process pressure: Max. 10 bar Upper signal level: 20 mA ... 20.5 mA Signal voltage LOW: ≤ 2 V Initialization time: ≤ 5 s Supply voltage: 18 V DC ... 30 V DC Conductivity: No limitation Maximum flow: 240 l/min Connection type: Round connector M12 x 1, 8-pin Power consumption: ≤ 180 mA Medium: Fluids Minimim flow: 5 l/min Impuls/frequency output: 0 kHz ... 10 kHz Output current: < 100 mA Protection class: III Housing material: PSU Process temperature: 0 °C ... +80 °C Ripple: ≤ 5 Vpp Inlet zone: 60 cm Wetted parts: PSU Capacitive load: 100 nF Enclosure rating: IP 67 Signal voltage HIGH: Vs - 2 V Repeatability: ≤ 0.5 % Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Accuracy of sensor element: 2 % (of final value) Output signal: Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature 2 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring 1 digital input for dosing and counter reset Weight: 460 g Ambient storage temperature: -20 °C ... +70 °C