Specification: Part Number 1065354 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe EMC: EN 61326-1:2006, 2004/108/EG Lower signal level: 3.8 mA ... 4 mA Inactive area at probe end: 10 mm Repeatability: ≤ 2 mm Housing design: With PMMA viewing window EHEDG approval: + Process connection: G ¾ A Inductive load: < 1 H Signal voltage LOW: ≤ 2 V Single- and continuous shock: EN 60068-2-27 Resolution: < 2 mm Housing material: 303 UL approval: + Ambient temperature operation: -20 °C ... +60 °C Process pressure: -1 bar ... 16 bar Supply voltage: 12 V DC ... 30 V DC Interference emission: EN 61000-6-4:2007 RoHS certificate: + Initialization time: ≤ 2 s Max.probe load: 6 Nm Power consumption: ≤ 75 mA at 24 V DC without output load Signal voltage HIGH: Vs - 2 V Process temperature: -20 °C ... +150 °C Output current: < 100 mA Protection class: III Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Accuracy of sensor element: ± 5 mm Medium: Fluids Conductivity: No limitation Inactive area at process connector: 25 mm Hysteresis: Min. 2 mm, free adjustable Capacitive load: 100 nF Connection type: Round connector M12 x 1, 5-pin Ambient storage temperature: -40 °C ... +80 °C Temperature drift: < 0.1 mm/K Interference resistance: EN 61000-6-2:2005 MTTF: 194.3 a (EN ISO 13849-1) Response time: < 400 ms Upper signal level: 20 mA ... 20.5 mA Probe length: 3,700 mm IO-Link: + Measurement: Switch, Continuous 3-A: - GOST approval: +