Specification: Part Number 1065349 Inductive load: < 1 H 3-A: - Probe length: 3,200 mm Inactive area at probe end: 10 mm Upper signal level: 20 mA ... 20.5 mA EMC: EN 61326-1:2006, 2004/108/EG Accuracy of sensor element: ± 5 mm Protection class: III Lower signal level: 3.8 mA ... 4 mA RoHS certificate: + Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Repeatability: ≤ 2 mm Connection type: Round connector M12 x 1, 5-pin IO-Link: + Initialization time: ≤ 2 s Ambient temperature operation: -20 °C ... +60 °C Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Measurement: Switch, Continuous Supply voltage: 12 V DC ... 30 V DC Single- and continuous shock: EN 60068-2-27 Temperature drift: < 0.1 mm/K Conductivity: No limitation Process temperature: -20 °C ... +150 °C Process connection: G ¾ A Signal voltage HIGH: Vs - 2 V Hysteresis: Min. 2 mm, free adjustable Housing design: With PMMA viewing window Max.probe load: 6 Nm Ambient storage temperature: -40 °C ... +80 °C EHEDG approval: + Capacitive load: 100 nF Signal voltage LOW: ≤ 2 V Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Interference emission: EN 61000-6-4:2007 MTTF: 194.3 a (EN ISO 13849-1) Medium: Fluids UL approval: + Interference resistance: EN 61000-6-2:2005 Housing material: 303 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK GOST approval: + Inactive area at process connector: 25 mm Power consumption: ≤ 75 mA at 24 V DC without output load Output current: < 100 mA Response time: < 400 ms Resolution: < 2 mm Process pressure: -1 bar ... 16 bar