Reverse polarity protection Yes (4.75...30 VDC) Approval UL approval / E63076 Connection Connector M23, 12-pin Cable 1 m GI332 output signals A 90° B, N + inverted Starting torque ≤0.03 Nm manufacter SKU GI332 Rotor moment of inertia 14.5 gcm² Protection DIN EN 60529 IP 54 Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) Interference immunity DIN EN 61000-6-2 Voltage supp
Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) Sensing method Optical Operating temperature -25...+100 °C (5 VDC) -25...+85 °C (24 VDC) -40...+85 °C (optional) Size (flange) ø58 mm Rotor moment of inertia 14.5 gcm² Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Operating speed ≤6000 rpm Reference signal Zero pulse, width 90°
Rotor moment of inertia 60 gcm² GI341 output signals A 90° B, N + inverted Operating temperature -20...+80 °C Pulses per revolution 5...2048 Output stages Linedriver/RS422 TTL Push-pull short-circuit proof Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Relative humidity 95 % non-condensing Connection Cable 1 m Shaft type ø10...15 mm (blin
Sensing method Optical Voltage supply 5 VDC ±10 % 4.75...30 VDC 10...30 VDC manufacter SKU GI342 Weight approx. 150 g Size (flange) ø58 mm GI342 output signals A 90° B, N + inverted Material Housing: carbon-fibre reinforced polyamide Operating temperature -20...+80 °C Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) Emitted interference DIN EN 61000-6-4 Interference immu
Shaft type ø9.52 mm solid shaft Pulses per revolution 5...6000 Interference immunity DIN EN 61000-6-2 Voltage supply 5 VDC ±10 % 4.75...30 VDC Size (flange) 63.5 x 63.5 mm Sensing method Optical manufacter SKU GI352 Flange Clamping flange square 63.5 x 63.5 mm Admitted shaft load ≤20 N axial ≤40 N radial Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) Materials H
Size (flange) ø58 mm Reverse polarity protection Yes (4.75...30 VDC) Emitted interference DIN EN 61000-6-4 Shaft type ø10 mm solid shaft Operating speed ≤10000 rpm Output frequency ≤150 kHz Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) GI355 output signals A 90° B, N + inverted Admitted shaft load ≤20 N axial ≤40 N radial Resistance DIN EN 60068-2-6 Vi
Approvals UL approval / E63076 SIL2 approval according to DIN EN 61508 (equivalent to PLd) Protection DIN EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms Admitted shaft load ≤20 N axial ≤40 N radial Reference signal Zero pulse 70...720° (Option) Rotor moment of inertia 14.5 gcm² Pulses per revolu
Interference immunity DIN EN 61000-6-2 manufacter SKU GPI0W Relative humidity 95 % non-condensing Flange Clamping or synchro flange Weight approx. 250 g GPI0W output signals A 90° B, 0 Reference signal Zero pulse, width 90° Sensing method Optical Rotor moment of inertia 14.5 gcm² Admitted shaft load ≤20 N axial ≤40 N radial Operating speed ≤10000 rpm Approval UL app
Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms Emitted interference EN 61000-6-3 Output frequency ≤120 kHz Operating temperature -30...+100 °C Size (flange) ø158 mm Sensing method Optical manufacter SKU HG 16 Approvals CE UL approval / E256710 Radial tolerance ±0.05 mm (with zero pulse) ±0.2 mm (without zero pulse) Pulses per revolution 250.
Rotor moment of inertia 18 gcm² Shaft type ø12...16 mm (blind hollow shaft) Operating speed ≤12000 rpm ≤30000 rpm (option) Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms Phase shift 90° ±20° Output frequency ≤120 kHz Scan ratio 40...60 % Weight approx. 180 g Protection DIN EN 60529 IP 55 (≤12000 U/min) IP 23 (≤30000 rpm) Int
Rotor moment of inertia 340 gcm² Explosion protection II 3 G Ex nA IIC T4 Gc (gas) II 3 D Ex tc IIIC T135°C Dc (dust) Reference signal Zero pulse, width 90° Materials Housing: aluminium die-cast Shaft: stainless steel Protection DIN EN 60529 IP 66 Sensing method Optical Shaft type ø12...20 mm (blind hollow shaft) ø17 mm (cone shaft 1:10) Operating torque typ. 6 Ncm manufacter SK
Switching delay time ≤40 ms Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 200 g, 6 ms Size (flange) ø105 mm Phase shift 90° ±20° Voltage supply 9...30 VDC Reference signal Zero pulse, width 90° Approval CE Switching accuracy ±2 % (Digit) Emitted interference EN 61000-6-3 Admitted shaft load ≤450 N axial ≤600 N radial Rotor moment of inert
Speed (n) ≤6000 rpm Operating temperature -30...+85 °C HOG 10 + DSL.R output signals K1, K2, K0 + inverted Connection Terminal box Size (flange) ø105 mm Switching outputs 3 outputs, speed control Protection DIN EN 60529 IP 66 Sensing method Optical Reference signal Zero pulse, width 90° Switching delay time ≤40 ms Output frequency ≤120 kHz Explosion protection I
Switching hysteresis =30 % of switching speed Output stages HTL-P (power linedriver) TTL/RS422 Output frequency ≤120 kHz ≤300 kHz (on request) manufacter SKU HOG 10 + ESL 90 Operating temperature -20...+85 °C Switching delay time ≤40 ms Transmission length ≤350 m at 100 kHz (HTL-P) ≤550 m at 100 kHz (TTL) Range of switching speed (ns) 650...6000 rpm Switching outputs 1 output, speed
Shaft insulation 2.8 kV Voltage supply 12 VDC ±10 % Consumption w/o load ≤5 mA Shaft type ø16...20 mm (blind hollow shaft) ø17 mm (cone shaft 1:10) Operating temperature -20...+85 °C Rotor moment of inertia 680 gcm² Operating speed ≤5000 rpm Protection DIN EN 60529 IP 66 Size (flange) ø105 mm Weight approx. 2.3 kg 2.5 kg (with option M) Pulses per revolu
Incremental encoders - combination HOG 10 + FSL TTL output driver for cable length up to 550 m Mechanical speed monitoring based on centrifugal force Hybrid bearing for extended service life Terminal boxes, turn by 180°
INCREMENTAL ENCODER ø12...20 mm (blind hollow shaft), ø17 mm (cone shaft 1:10). Optical sensing, blind hollow shaft. Catalogue number 700000682675. Incremental encoders Baumer Hubner HOG 10 DN 1024 I series are designed for equipment where very high resistance to shock and vibrations are required. Also they have hybrid bearing for extended lifetime. The main characteristics of HOG 10 DN 1024
Weight approx. 2.9 kg 3.3 kg (with option M) Materials Housing: aluminium die-cast Shaft: stainless steel Approvals CE UL approval / E256710 Sensing method Optical Connection 2x terminal box 4x terminal box (with option M) Reference signal Zero pulse, width 90° Shaft type ø16...20 mm (blind hollow shaft) ø17 mm (cone shaft 1:10) Size (flange) ø105 mm Operating speed ≤6000
Shaft type ø12...20 mm (blind hollow shaft) ø17 mm (cone shaft 1:10) Admitted shaft load ≤450 N axial ≤600 N radial Reference signal Zero pulse, width 90° Shaft insulation 2.8 kV Sensing method Optical Materials Housing: aluminium die-cast Shaft: stainless steel Output frequency ≤120 kHz ≤300 kHz (on request) Scan ratio 40...60 % Rotor moment of inertia 340 gcm²
Switching hysteresis =30 % of switching speed Switching delay time ≤40 ms Reference signal Zero pulse, width 90° Output frequency ≤120 kHz ≤300 kHz (on request) Voltage supply 9...30 VDC; 5 VDC ±5 % Size (flange) ø105 mm Emitted interference EN 61000-6-3 Approval CE Operating temperature -20...+85 °C Transmission length ≤350 m at 100 kHz (HTL-P) ≤550 m at 100 kHz (TT
Emitted interference EN 61000-6-3 Scan ratio 40...60 % Operating torque typ. 6 Ncm Reference signal Zero pulse, width 90° Shaft insulation 2.8 kV Output switching capacity ≤6 A / 230 VAC ≤1 A / 125 VDC Interference immunity EN 61000-6-2 Transmission length ≤350 m at 100 kHz (HTL-P) ≤550 m at 100 kHz (TTL) Operating temperature -40...+100 °C -25...+100 °C (>3072 pulses per revolution