Emitted interference EN 61000-6-3 Scan ratio 40...60 % Operating torque typ. 6 Ncm Reference signal Zero pulse, width 90° Shaft insulation 2.8 kV Output switching capacity ≤6 A / 230 VAC ≤1 A / 125 VDC Interference immunity EN 61000-6-2 Transmission length ≤350 m at 100 kHz (HTL-P) ≤550 m at 100 kHz (TTL) Operating temperature -40...+100 °C -25...+100 °C (>3072 pulses per revolution) -50...+100 °C (optional) Pulses per revolution 300...5000 HOG 11 + FSL output signals K1, K2, K0 + inverted Error output (only EMS) Output frequency ≤120 kHz ≤300 kHz (on request) Admitted shaft load ≤450 N axial ≤600 N radial Rotor moment of inertia 680 gcm² Minimum switching current 50 mA Shaft type ø16...20 mm (blind hollow shaft) ø17 mm (cone shaft 1:10) Voltage supply 9...30 VDC 5 VDC ±5 % Resistance IEC 60068-2-6 Vibration 5 g, 10-2000 Hz IEC 60068-2-27 Shock 50 g, 11 ms Output stages HTL-P (power linedriver) TTL/RS422 Phase shift 90° ±20° Weight approx. 2.2 kg 2.4 kg (with option M) Switching deviation cw-ccw rotation ≤3 % Protection DIN EN 60529 IP 67 Size (flange) ø105 mm manufacter SKU HOG 11 + FSL Switching outputs 1 output, speed control Approval CE Materials Housing: aluminium die-cast Shaft: stainless steel Range of switching speed (ns) 850...4500 rpm (Δn = 2 rpm/s) Consumption w/o load ≤100 mA Switching hysteresis ~40 % of switching speed Speed (n) ≤1.25 · ns Sensing method Optical Switching accuracy ±4 % (Δn = 2 rpm/s); = +20 % (Δn = 1500 rpm/s) Connection 2x terminal box 3x terminal box (with option M)