Admitted shaft load ≤250 N axial ≤400 N radial Connection Terminal box Consumption w/o load ≤100 mA Location classes DNV Temperature: D Humidity: B Vibration: B EMC: B Enclosure: C manufacter SKU HOG 11 DNV Operating torque typ. 6 Ncm HOG 11 DNV output signals K1, K2, K0 + inverted Resistance IEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 ms Weight approx. 1.6 kg Protection DIN EN 60529 IP 67 Approvals CE UL approval / E256710 DNV approval Operating temperature -40...+100 °C Shaft type ø16 mm (blind hollow shaft) Interference immunity EN 61000-6-2 Size (flange) ø105 mm Reference signal Zero pulse, width 90° Phase shift 90° ±20° Pulses per revolution 300...2500 Materials Housing: aluminium die-cast Shaft: stainless steel Sensing method Optical Output frequency ≤120 kHz Voltage supply 9...30 VDC 5 VDC ±5 % Output stages HTL-P (power linedriver) TTL/RS422 Rotor moment of inertia 340 gcm² Scan ratio 30...70 % Operating speed ≤6000 rpm (mechanical) Transmission length ≤350 m at 100 kHz (HTL-P) ≤550 m at 100 kHz (TTL) Emitted interference EN 61000-6-3 Shaft insulation 2.8 kV