Pulses per revolution 5...6000 Emitted interference DIN EN 61000-6-4 Relative humidity 95 % non-condensing Operating temperature -25...+100 °C (5 VDC) -25...+85 °C (24 VDC) -40...+85 °C (optional) Sensing method Optical Connection Connector M23, 12-pin Cable 1 m Consumption w/o load ≤30 mA (24 VDC) ≤60 mA (5 VDC) Flange Synchro flange manufacter SKU GI356 Weight approx. 250 g Rotor moment of inertia 14.5 gcm² Admitted shaft load ≤20 N axial ≤40 N radial Output frequency ≤150 kHz Reverse polarity protection Yes (4.75...30 VDC) Materials Housing: aluminium Flange: aluminium Size (flange) ø58 mm Approval UL approval / E63076 Reference signal Zero pulse, width 90° Voltage supply 5 VDC ±10 % 4.75...30 VDC 10...30 VDC GI356 output signals A 90° B, N + inverted Interference immunity DIN EN 61000-6-2 Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Protection DIN EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Operating speed ≤10000 rpm Output stages Linedriver/RS422 Push-pull short-circuit proof Shaft type ø6 mm solid shaft Starting torque ≤0.015 Nm (IP 54) ≤0.03 Nm (IP 65)